DCA-70SSJU SERIES — ENGINE OPERATING PANEL
Figure 6. Engine Operating Panel Up To S/N 73002140
The definitions below describe the controls and functions of the
1.Panel Light – Normally used in dark areas or at night time. When activated, panel lights will illuminate. When the generator is not in use be sure to turn the panel light switch to the OFF position.
2.Panel Light Switch – When activated will turn on control panel light.
3.Oil Pressure Gauge – During normal operation this gauge be should read in the “GREEN” zone. When starting the generator the oil pressure may read a little bit higher, but after the engine warms up the oil pressure should return to the green zone.
4.WaterTemperature Gauge – During normal operation this gauge be should read in the “GREEN” zone.
5.Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.
6.Fuel Gauge - Indicates amount of diesel fuel available.
7.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.
8.Engine SpeedThrottle- This lever controls the speed of the engine (low or high).
9.Ignition Switch – Turns the engine on, off or to preheat the engine.
10.Cold Starting Button – Used to warm the engine glow plugs in cold weather conditions. Press and hold the engine cold starting button until the button illuminates.
11.Water Temperature Warning Light - Indicates if the coolant is low. This warning will shut off the engine.
12.Oil Pressure Warning Light - This will indicate if the oil pressure is too low or high. This warning will shut off the engine.