Output Terminal Panel Available Voltages
DCA-500SSK — OUTPUTTERMINAL
CAUTION:
A wide range of voltages are available to supply load to many different applications. Voltages may be selected by using the voltage
NEVER attempt to change the Voltage
|
| TABLE 8. VOLTAGES AVAILABLE |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| ||
MODEL | DCA500SSK |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
3 PHASE VOLTAGE | 208 VOLT |
| 220 VOLT |
| 240 VOLT |
| 416 VOLT |
| 440 VOLT | 480 VOLT | ||
(RECONNECTABLE) |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
SINGLE PHASE | 120 VOLT |
| 127 VOLT |
| 139 VOLT |
| 240 VOLT |
| 254 VOLT | 277 VOLT | ||
(ADJUSTABLE) |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
Over Current Relay |
|
|
|
|
| Maximum Amps |
|
|
| |||
An over current relay is connected to the circuit breaker. |
|
|
| |||||||||
The following table below shows the maximum amps the | ||||||||||||
During an over current situation, both the circuit breaker and | ||||||||||||
the over current relay may trip. If the circuit breaker can not | generator can provide Do not exceed the maximum amps | |||||||||||
be reset, the reset button on the over current relay must be | listed below. |
|
|
|
| |||||||
pressed. The over current relay is located on the control |
|
|
|
|
|
| ||||||
box. |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Table 9. | Maximum Amps |
|
|
| |||||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
| Model: | DCA500SSK |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Rated | Maximum Amps |
|
|
| ||||
|
|
|
| Voltage |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
| Single Phase | 1111.1 amps (4 wire) |
|
|
| |||||
|
|
|
| 120 Volt |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
| Single Phase | 555.6 amps (4 wire) |
|
|
| |||||
|
|
|
| 240 Volt |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
| Three Phase | 1202.8 amps |
|
|
| |||||
|
|
|
| 240 Volt |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
| Three Phase | 601.4 amps |
|
|
| |||||
|
|
|
| 480 Volt |
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
PAGE 38 —