General Inspection

Prior to each use, the generating set should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel or oil leaks.

Air Cleaner

Every 50 hours: If dust indicator is red, clean the air cleaner element.

Outer Element:

1.Loosen wing bolt, remove dust cup, then remove wing nut and take out element.

2.Clean the inside of the body and cover using a damp cloth.

3.Blow dry with compressed air (0.69Mpa [7kgf.cm2, 99.4 PSI] maximum) against the side of the element along the pleats. Then blow dry against outside along the pleats, then against inside again.

4.Remove one seal each time the element is cleaned.

5.Replace the outer element after cleaning it 6 times or after one year. Replace the outer element if indicator is red even after cleaning it.

6.Check the inner cylinder element clamping nut for looseness, and retighten if necessary.

7.If seal washer is damaged or the threads of wing nut are damaged, replace.

8.Remove evacuator valve and clean it with compressed

air. Reinstall.

Inner element (if equipped)

1.Remove the cover and outer element, then remove the inner element.

2.Cover the air connector opening (outer side) with clean cloth or cloth tape.

3.Clean the inside of the body. Remove air connector opening protection.

4.Install a new inner cylinder element to the cylinder and tighten the nut.

5.Install element.

6.After replacing the element, press the button of the dust indicator to return the red piston to its original position.

DCA-500SSK — MAINTENANCE

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents. During cold weather, the greater the empty volume inside the tank, the easier it is for water to condense. This can be reduced by always keeping the tank as full as possible.

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure.

To restart after running out of fuel, turn the key switch to the “START” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Service Daily

If engine is operating in very dusty and dry grass conditions, a clogged air cleaner will result in high fuel consumption, loss of power and excessive carbon buildup in the combustion chamber.

Cleaning the Fuel Strainer

Clean the fuel strainer if it contains dust or water. Remove dust or water in the strainer cap and wash it in diesel. Securely fasten the fuel strainer cap so that fuel will not leak. Check the fuel strainer every 200 hours of operation or once a month.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 14, page 39.

Flushing Out Radiator and Changing Coolant

1.Stop the engine and allow to cool. Tighten valve of the corrosion resistor (if equipped).

2.Turn water filer cap slowly and remove it.

3.Prepare a container to catch the coolant, then open drain plug of the radiator or heat exchanger and drain plug of the engine, and drain the coolant.

4.After draining the coolant, close drain plugs and fill with tap water.

PAGE 56 — DCA-500SSK — PARTS AND OPERATION MANUAL (STD) — REV. #1 (04/14/01)

Image 56
Contents MQ Power Model DCA-500SSK Whisperwatttm Generator Page Heres HOW to GET Help Table of Contents Earn Extra Discounts when You order by FAX Parts Ordering ProceduresGeneral Safety Rules for Safe OperationRadiator Battery Loading and Unloading CraneRules for Safe Operation Towing Safety Precautions DCA-500SSK -TOWINGDCA-500SSK TRAILER-SAFETY Guidelines Explanation of ChartDCA-500SSK -TRAILER-SPECIFICATIONS DCA-500SSK -TRAILER-SPECIFICATIONS ElectricalElectric Brakes Electric Brake AdjustmentBrakes DCA-500SSK -TRAILER Safety Guidelines Hydraulic/Air/Surge BrakesSuspension Tires/Wheels/Lug NutsTire Wear/Inflation Lug Nut Torque Requirements DCA-500SSK -TRAILER Safety GuidelinesTorque Ft.-Lbs DCA-500SSK -TRAILER-WIRING Diagram DCA-500SSK -TRAILER Brakestroubleshooting Symptom Possible Cause SolutionDCA-500SSK Operation and Safety Decals Machine Safety DecalsDCA-500SSK Operation and Safety Decals DCA-500SSK Operation and Safety Decals DCA-500SSK Operation and Safety Decals DCA-500SSK Operation and Safety Decals DCA-500SSK -- Notes DCA-500SSK Specifications DCA-500SSK General Information DCA-500SSK Major Components Major ComponentsPage DCA-500SSK Dimensions TOP and Side DimensionsDCA-500SSK Dimensions Front and Rear DCA-500SSK Control Panel Control PanelDCA-500SSK Control Panel Pilot Lamp Indicates that the generator is working properlyDCA-500SSK Engine Operating Panel Engine Operating PanelFuel Level Gauge Indicates amount of diesel fuel remaining DCA-500SSK Outputterminal Output Terminal Panel Location Output Terminal Panel Available Voltages Over Current Relay Maximum AmpsModel Rated Maximum AmpsReading the Output Terminal Gauges AC VoltmeterSingle Phase, 240 Volt Phase, 240 VoltSingle Phase, 139 Volt Voltage Change-over BoardSingle Phase, 480 Volt Phase, 480 VoltSingle Phase, 277 Volt DCA-500SSK OutputterminalDCA-500SSK Installation Outdoor InstallationDCA-500SSK Installation Typical Generator Grounding ApplicationDCA-500SSK PRE-SETUP General Inspection Prior to OperationType Oil RangeCleaning the Radiator Air CleanerOperation in Freezing Weather Fan Belt TensionPiping and Hose Connection Battery Cable InstallationWiring DCA-500SSK Load Application Single Phase LoadThree Phase Load Before Starting Engine Before Starting Generator and Control PanelSet the battery ON/OFF switch to the on position Voltage Meter Volts Engine Speed Switch DCA-500SSK Generator START-UP Procedure Auto Emergency Stop DCA-500SSK Generator Shutdown ProcedureEngine Shutdown Page DCA-500SSK Maintenance Replacing fuel filter Check Electric Heater If equippedChanging Oil Generator Storage Cleaning breather elementGreasing Inspection / Maintenance DCA-500SSK-GENERATORWIRING Diagram DCA-500SSK-ENGINEWIRING Diagram DCA-500SSK -TROUBLESHOOTING Engine DCA-500SSK -TROUBLESHOOTING Engine Engine TroubleshootingDCA-500SSK -TROUBLESHOOTING GENERATOR/ENGINE Generator TroubleshootingDCA-500SSK -TROUBLESHOOTING Mpec Mpec TroubleshootingExplanation of Code in Remarks Column Items Found In the Items Number ColumnQty Description DCA-500SSK Suggested Spare PartsDCA-500SSK w/SA6D170AE-1 Komatsu Engine DCA-500SSK Generator Assy Part Name QTY DCA-500SSK Generator Assy DCA-500SSK Generator Assy DCA-500SSK Control BOX Assy Part Name DCA-500SSK Control BOX Assy APS Unit DCA-500SSK Engine & Radiator Assy Part Name QTY Remarks DCA-500SSK Engine & Radiator Assy 0131710060 DCA-500SSK Engine Operating Panel Assy Support LEG DCA-500SSK Engine Operating Panel Assy Starter Switch DCA-500SSK Outputterminal Assy Output Terminal DCA-500SSK Outputterminal Assy Cover DCA-500SSK Battery Assy Battery DCA-500SSK Muffler Assy Muffler DCA-500SSK Fueltank Assy Fuel Tank DCA-500SSK Enclosure #1 Assy Enclosure #1 AssyDCA-500SSK Enclosure #1 Assy DCA-500SSK Enclosure #1 Assy HEX.NUT DCA-500SSK Enclosure #2 Assy Enclosure #2 AssyRear Frame DCA-500SSK Enclosure #2 Assy DCA-500SSK Enclosure #2 Assy DCA-500SSK Enclosure #3 Assy Enclosure #3 AssyDCA-500SSK Enclosure #3 Assy DCA-500SSK Enclosure #3 Assy 7525151504 DCA-500SSK Rubber Seal Assy 0228901640 DCA-500SSK Nameplate and Decals Control BOX Group DCA-500SSK Nameplate and Decals Part Name QTY Remarks Terms and Conditions of Sale Parts Freight PolicyPage Mail mq@multiquip.com WWW multiquip.com