Kohler 9EFOZ/10EOZ, 8.5EFOZ, 80EFOZ/99EOZ manual Exhaust System Location, Mounting, and Installation

Page 22

4.3Exhaust System Location, Mounting, and Installation

Mount the silencer independently to eliminate stress on the exhaust system and the exhaust manifold/mixer elbow. See Section 7 for the mixer elbow water line hose size. See Figure 4-1 for the exhaust connection to the mixer elbow. Provide an adequate hose length from the exhaust mixer to the silencer to allow for generator set movement.

 

1

1. Water/exhaust outlet

TP-5586-6

 

Figure 4-1 Mixer Elbow/Exhaust Connection, Typical

1

TP-6134-

1. Water/exhaust outlet

Figure 4-2 Mixer Elbow/Exhaust Connection, 3.5EFOZ/4EOZ Model Only

Locate the exhaust outlet at least 10 cm (4 in.) above the waterline when the craft is loaded to maximum capacity. Install an exhaust port with the flap at the exhaust (transom) outlet to prevent water backup in following seas or when moving astern (backward). A lift in the exhaust piping before the piping exits the craft prevents backwash. See Figure 4-4, item 1. Support the exhaust lines to prevent the formation of water pockets.

Exhaust system installation guidelines for various generator set locations follow. Information and illustrations of stern- (rear) exhaust installations also apply to side-exhaust installations. Where exhaust lines require passage through bulkheads, use port (left)- or starboard (right)- side exhaust outlets, also in applications in which long exhaust lines to the transom (rear) could cause excessive back pressure. See Figure 4-3 for allowable back pressures. Should any information regarding installation conflict with USCG Regulations, follow USCG Regulations.

 

Allowable Exhaust

 

Back Pressure,

Model

kPa (mm H2O)

4/8.5/9/23/27EFOZ and

9.81

(1000)

5/10/28/32EOZ

 

 

 

 

 

6.5EFOZ and 8EOZ

11.77

(1200)

 

 

 

11/16/17.5EFOZ and 13/20EOZ

6.37

(650)

 

 

 

3.5/11.5/13/19/20EFOZ and

4.90

(500)

4/14/15.5/23/24EOZ

 

 

 

 

 

33/40/55/70/80/100/125EFOZ

7.47

(762)

and 40/50/65/80/99/125/150EOZ

 

 

 

 

 

Figure 4-3 Allowable Exhaust Back Pressures

4.3.1Above-Waterline Installation

Install a customer-supplied silencer with the silencer’s outlet at a maximum of 3 m (10 horizontal ft.) from the center of the engine’s exhaust outlet. See Figure 4-4. Mount a typical silencer with the inlet and outlet horizontal and with the drain plug down. Use an exhaust hose pitch of at least 13 mm per 30.5 cm (0.5 in. per running foot). Some silencers require two support brackets or hanger straps for installation to stringers or other suitable structure. Follow the instructions provided with the silencer. Install any lift (see Figure 4-4, item 1) in the exhaust line below the engine exhaust manifold outlet.

12 Section 4 Exhaust System

TP-6069 6/03

Image 22
Contents Models TP-6069 6/03dPage Table of Contents Page Battery Safety Precautions and InstructionsAccidental Starting Engine Backfire/Flash Fire Exhaust SystemHazardous Noise Fuel SystemHazardous Voltage/ Electrical Shock Hot Parts Hot coolant and steam Can cause severe injury or deathMoving Parts VI Safety Precautions and Instructions TP-6069 6/03 Introduction Typical Generator Set Location and MountingIntroduction TP-6069 6/03 General Considerations Installation Location ConsiderationsLocation and Mounting LocationLocation and Mounting TP-6069 6/03 Cooling System Components Cooling SystemVentilation Intake Through-Hull Strainer Seacock CoverWater Lines SeacockSeawater Strainer Closed Heat Exchanger 125EFOZ/5--150EOZ ModelsArrow Description 40--150EOZ Models Direct Water-Cooled Cooling System 3.5EFOZ and 4EOZ Models Cooling System TP-6069 6/03 Types Exhaust SystemExhaust Lines Exhaust System Location, Mounting, and Installation Above-Waterline InstallationTypical Above-Waterline Installation 2 Mid/Below-Waterline Installation Typical Mid and Below Waterline Installation Exhaust System TP-6069 6/03 Fuel System Fuel TankFuel Pump Lift Fuel LinesFuel Filters Fuel ConsumptionCircuit Protection Electrical SystemAC Voltage Connections Circuit Breaker ConsiderationsAC Circuit Breaker Ratings 33--150 kW Circuit Breaker Installation 27EFOZ and 5--32EOZ Models Electrical System TP-6069 6/03 Pleasurecraft Installation Regulations Installation In Steel or Aluminum VesselsInstallation Regulations Commercial Vessel Installation RegulationsWiring CCARemote Start Switch Connection Remote Controller and Harness Options 33--150 kW Models 10 Remote Controller and Harness Options 33--150 kW Models Electrical System TP-6069 6/03 Installation Drawings Installation DrawingsDimension Drawing, 3.5EFOZ/4EOZ Remote Options, 3.5EFOZ/4EOZ Dimension Drawing, 4EFOZ/5EOZ Dimension Drawing, 4EFOZ/5EOZ with Sound Shield Dimension Drawing, 6.5EFOZ/8EOZ Dimension Drawing, 6.5EFOZ/8EOZ with Sound Shield Dimension Drawing, 8.5/9EFOZ and 10EOZ Dimension Drawing, 8.5/9EFOZ and 10EOZ with Sound Shield 10 Dimension Drawing, 11EFOZ/13EOZ 11 Dimension Drawing, 11EFOZ/13EOZ with Sound Shield 12 Dimension Drawing, 11.5/13EFOZ and 14/15.5EOZ ADV-6513B-C 14 Dimension Drawing, 16/17.5EFOZ and 20EOZ ADV-6481B-D 16 Dimension Drawing, 19/20EFOZ and 23/24EOZ ADV-6494B-C 18 Dimension Drawing, 23/27EFOZ and 28/32EOZ ADV-6285B-F 20 Dimension Drawing, 33EFOZ/40EOZ ADV-6581B-E 22 Dimension Drawing, 33EFOZ/40EOZ with Sound Shield 23 Dimension Drawing, 33EFOZ/40EOZ with Electric Clutch 24 Dimension Drawing, 40EFOZ/50EOZ ADV-6582B-E 26 Dimension Drawing, 40EFOZ/50EOZ with Sound Shield 27 Dimension Drawing, 40EFOZ/50EOZ with Electric Clutch 28 Dimension Drawing, 55EFOZ/65EOZ ADV-6583B-E 30 Dimension Drawing, 55EFOZ/65EOZ with Sound Shield 31 Dimension Drawing, 55EFOZ/65EOZ with Electric Clutch 32 Dimension Drawing, 70/80EFOZ and 80/99EOZ ADV-6603B-D ADV-6603C-D ADV-6603D-D 36 Dimension Drawing, 100/125EFOZ and 125/150EOZ ADV-6594B-D ADV-6594C-D 2 100--120/200--240-Volt Configurations Reconnection/Adjustments1 100--120-Volt Configurations Four-Lead Reconnection3 200--240-Volt Configurations Twelve-Lead ReconnectionVoltage Adjustment Overvoltage adjustment potentiometer R41 LED4 red Marine Manual Ship-to-Shore Transfer Switch Voltage Regulator Adjustment 4-27EFOZ and 5-32EOZ Models Stab13 Governor Adjustment 4EFOZ/5EOZ shown Reconnection/Adjustments TP-6069 6/03 Appendix a Generator Selection and Wattage Requirements MotorsAppendix B Abbreviations AnsiLCB Appendix C Generator Set Output Ratings Procedure Generator OutputPage Page Page 2000, 2001, 2002, and 2003 by Kohler Co. All rights reserved