Appendix C Generator Set Output Ratings Procedure
Kohler Co. develops the kilowatt output rating of a Kohlerr marine generator set based upon the calculations specified in ISO 3046 and ISO
generator set installation. Figure 1 outlines the calculations. Figure 2 contains examples of how heat variables affect generator set ratings.
Generator Output corrected = Generator Output observed x Correction Factor
Output power is expected to be within ±5% of the specified rating when corrected to reference conditions. Correction factors are determined using the following formulas:
1.For naturally aspirated
xAlternator Efficiency Reference / Alternator Efficiency Observed
2.For turbocharged compression ignition engines:
C.F. = [1.175 (29.2 / Barometer Observed in. Hg).7 (Temperature _F + 460/537)2
xAlternator Efficiency Reference / Alternator Efficiency Observed
3.For turbocharged and intercooled compression ignition engines:
C.F. = [1.175 (29.2 / Barometer Observed in. Hg).7 (Temperature _F + 460/537)1.2
xAlternator Efficiency Reference / Alternator Efficiency Observed
Reference conditions:
Temperature: 77_F; Pressure: 29.2 in. Hg dry barometer.
Kohler sound shield increases ambient intake air approx. 12_F
Approximate derates:
Temperature: approximately 1% per 10_F (turbocharged engines have a greater derate);
Pressure (altitude): approximately 4% per 1000 ft. (1 in. Hg)
Figure 1 Generator Output
KEY |
|
|
|
|
|
|
|
|
|
|
60 Hz | 8.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
50 Hz | 7.9 |
|
|
|
|
|
|
|
|
|
| 7.8 |
|
|
|
|
|
|
|
|
|
| 7.7 |
|
|
|
|
|
|
|
|
|
| 7.6 |
|
|
|
|
|
|
|
|
|
| 7.5 |
|
|
|
|
|
|
|
|
|
| 7.4 |
|
|
|
|
|
|
|
|
|
| 7.3 |
|
|
|
|
|
|
|
|
|
| 7.2 |
|
|
|
|
|
|
|
|
|
| 7.1 |
|
|
|
|
|
|
|
|
|
| 7.0 |
|
|
|
|
|
|
|
|
|
| 6.9 |
|
|
|
|
|
|
|
|
|
| 6.8 |
|
|
|
|
|
|
|
|
|
| 6.7 |
|
|
|
|
|
|
|
|
|
| 6.6 |
|
|
|
|
|
|
|
|
|
| 6.5 |
|
|
|
|
|
|
|
|
|
| 6.4 |
|
|
|
|
|
|
|
|
|
| 6.3 |
|
|
|
|
|
|
|
|
|
| 6.2 |
|
|
|
|
|
|
|
|
|
| 6.1 |
|
|
|
|
|
|
|
|
|
| 6.0 |
|
|
|
|
|
|
|
|
|
| 5.9 |
|
|
|
|
|
|
|
|
|
| 5.8 |
|
|
|
|
|
|
|
|
|
| 5.7 |
|
|
|
|
|
|
|
|
|
| 5.6 |
|
|
|
|
|
|
|
|
|
| 5.5 |
|
|
|
|
|
|
|
|
|
| 77 | 80 | 85 | 90 | 95 | 100 | 105 | 110 | 115 | 120 |
|
|
|
|
| Temperature (_F) |
|
|
|
| |
Figure 2 Example: 6.5EFOZ/8EOZ kW Derates (ISO 3046/ISO |
|
|
|