Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ installation manual Appliance Loads, Kilowatt Derating

Page 64

Capabilities will vary according to Kilowatt Derating following.

Motor

 

Starting

Running

Requirements

(In-Rush)

(HP)

 

Watts

Watts

1/4

 

750

330

1/3

 

1000

400

1/2

 

1500

600

3/4

 

2000

750

1

 

3300

1100

2

 

4000

2000

3

 

5000

3000

 

Figure 6-1. Motor Requirements

 

 

 

“Power to

 

 

Will Operate Air

Spare” for

 

 

Lighting

Model

Wattage

Conditioner of

Appliances,

Size Indicated

Tools

4CZ

4000

One 13,500 Btu

2100

6.5 CZ

6500

One 13,500 Btu

4600

 

 

Two 13,500 Btu

2700

Figure 6-2. Air Conditioner Requirements (50 Hz units will have slightly lower “power to spare” figures than those indicated)

Appliance Loads

Marine generator sets are often used to furnish AC for appliances such as TV, stereo, electric water heaters, etc. With the exception of the resistance-type loads such as the water heater, requirements for appliances are usually low. Such loads must not, however, be overlooked when figuring total requirements. Reserve capacity should be available for anticipated appliance loads to avoid overloading of a set. The average power requirements of some common electrical appliances are given in Figure 6-3.

Kilowatt Derating

Units are rated as listed below at 1.0 power factor. Derate the listed rating by approximately 3.5% per 1000 ft. (300 m) when the unit is operated at altitudes of 500 ft. (150 m) or more above sea level.

3.5CFZ, 50 Hz: 3.5 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).

4CZ, 60 Hz: 4 kW at 77_F (25_C) and 3.5 kW at 122_F (50_C).

5CFZ, 50 Hz: 5 kW at 77_F (25_C) and 4.85 kW at 122_F (50_C).

6.5CZ, 60 Hz: 6.5 kW at 77_F (25_C) and 6 kW at 122_F (50_C).

 

Motor

 

Electrical

Starting

Running

Appliance

Watts

Watts

Automatic Pilot

--

150--250

Blanket, Electric

--

50--250

Blender

800

600

Broiler

--

1350

Depthometer

--

25--1000

Drill, 3/8”

600

350

Dryer, Hair

--

850--1200

Fan, Air

50--200

25--100

Circulating

 

 

Food, Mixer

400

235

Heater, Space

--

750--1500

Heater, Water

--

1500

Iron

--

900--1200

Light Bulbs

--

(as indicated)

Pan, Frying

--

1200

Percolator,

--

650

Coffee

 

 

Radar

--

750--1500

Radio

--

50--100

Radiophone

--

100--200

Range, Electric

--

1000--1500

(per element)

 

 

Soldering Gun

--

250

Television

--

300--750

Toaster

--

750--1200

Water System

500--1500

300--1250

Figure 6-3. Appliance Average Wattage Ratings

(60 Hz)

6-2 Installation

TP-5695 12/93

Image 64
Contents Marine Generator Sets Models5CFZ 5CZCalifornia Proposition Table of Contents Safety Precautions and Instructions Carbon monoxide Can cause severe nausea, fainting, or death Carbon monoxide can cause severe nauseaSulfuric acid in batteries Can cause severe injury or death Sulfuric acid in batteries can cause severe injury orExplosive fuel vapors Can cause severe injury or death Explosive fuel vapors can cause severe injury orAccidental starting Can cause severe injury or death Accidental starting can cause severe injury orRotating parts Can cause severe injury or death Flying projectiles can cause severe injury or deathFire Can cause severe injury or death Sudden backfire can cause severe injury or deathSudden flash fire can cause severe injury or death Hazardous noise Can cause loss of hearing246242 Reference Material Pleasure CraftCommercial Vessels Additional ReferencesRoutine Service Parts Part Description Kohler Part NoGlossary of Abbreviations Abbreviation DescriptionNEC Specifications SpecificationsGeneral Specifications IntroductionGenerator 5CFZ/4CZ 5CFZ/6.5CZEngine GX360EVBPR4HS NGK Accessories Service Views Service Views typicalOperation Prestart ChecksController ControllerStarting StoppingEngine Safety Shutdown Switches Circuit ProtectionHigh Water Temperature Shutdown Switch Remote Panel Features Remote Panels OptionalRemote Start and Four-Meter Features Remote Start and Four-Meter Panel KitScheduled Maintenance Service Schedule Or 2 YearsGenerator Specifications Lubrication SystemAdding Oil Oil Change/Oil Filter ChangeFuel System Removing Oil FilterFuel Pump Screen Fuel Pump ScreenCarburetor Adjustments Carburetor/Choke LubricationIgnition System Ignition System ServiceSpark Plugs Problem Means of Identification Possible Cause Normal Gap bridgedOil fouled Carbon fouled12. Checking Spark Plug Gap Filling and Checking Cooling Systems- Closed/Heat ExchangerHot coolant and steam Can cause severe injury or death 14. Air-Bleed Screw Flushing and Cleaning TP-5695 12/93 Scheduled Maintenance Anticorrosion Zinc 17. Removing Anticorrosion ZincAir Cleaner Mixing Elbow Servicing Air CleanerPressure Cap Servicing Mixing ElbowBattery CleaningChecking Electrolyte Level Checking Specific Gravity21. Specific Gravity Temperature Correction ChargingValve Adjustment 22. Determining Top Dead Center Governor Governor AdjustmentLubrication Wattage Requirements Generator ServiceGeneral Storage Procedure Troubleshooting EngineUnit cranks but will Not startLacks power Problem Possible Cause Corrective Action Stops suddenlyOperates erratically Electrical System Generator Wiring Diagrams Schematic Wiring Diagram--3.5CFZ, 4CZ, 5CFZ, and 6.5CZDiagrams 4CZTo Generator To Shore Set Power Wire Generator SetsTo Load LO Neutral Ground Load SideLine Side 60 HzL1--L3 Without Jumper LeadPage Generator Selection and Wattage Requirements InstallationMotor Loads Appliance Loads Kilowatt DeratingTypical Location and Mounting LocationVentilation SpaceMounting Air Requirements CFM L/min Model Combustion CoolingFuel Systems Fuel SupplyAnti-Siphon Provisions Fuel LinesFuel Pump Lift Capabilities Fuel Consumption Max. Lift ft. m In. mmCooling Systems 11. Intake StrainerClosed/Heat Exchanger 13. Seawater StrainerExhaust Systems 15. Closed/Heat Exchanger Cooling System17. Typical Above Waterline Installation Carbon monoxideAbove Waterline Mid/Below WaterlineElectrical Systems Installation in Steel or Aluminum VesselsAC Voltage Connections Battery WiringRemote Start Switch Connection Lead Designations Pin FunctionDimension Drawing--3.5CFZ, 4CZ, 5CFZ, and 6.5CZ SectionSound Shield--Optional on 3.5CFZ and 4CZ Standard on 5CFZ and 6.5CZFor Sales & Service in U.S.A. & Canada Phone Parts Ordering InstructionsOperating Hour Service Log Kohler CO. KOHLER, Wisconsin 53044 Phone