Kohler 3.5CFZ, 4CZ, 5CFZ, 6.5CZ Accidental starting Can cause severe injury or death

Page 8

ACCIDENTAL STARTING

WARNING

Accidental starting.

Can cause severe injury or death.

Disconnect battery cables before working on generator set (negative lead first and reconnect it last).

Accidental starting can cause severe injury or

death. Disconnect battery cables (remove negative lead first and reconnect it last) to disable generator set before working on any equipment connected to generator. The generator set can be started by remote start/stop switch unless this precaution is followed.

MOVING PARTS

WARNING

Rotating parts.

Can cause severe injury or death.

Do not operate generator set without all guards, screens, or covers in place.

Flying projectiles can cause severe injury or death.

Retorque all crankshaft and rotor hardware after servicing. When making adjustments or servicing generator set, do not loosen crankshaft hardware or rotor thru-bolt. If rotating crankshaft manually, direction should be clockwise only. Turning crankshaft bolt or rotor thru-bolt counterclockwise can loosen hardware and result in serious personal injury from hardware or pulley flying off engine while unit is running.

Exposed moving parts can cause severe injury or

death. Additional Precautions Regarding Sound Shield Equipped Models:

Some scheduled maintenance procedures require the generator set to be running while performing service. If the sound shield has been removed leaving belts and pulleys exposed, be especially careful of this area.

Exposed moving parts can cause severe injury or

death. Keep hands, feet, hair, clothing, and test leads away from belts and pulleys when unit is running. Replace guards, covers, and screens before operating generator set.

HOT PARTS

WARNING

Hot engine and exhaust system.

Can cause severe injury or death.

Do not work on generator set until unit is allowed to cool.

Hot parts can cause severe injury or death. Do not touch hot engine parts. An engine gets hot while running and exhaust system components get extremely hot.

WARNING

Hot coolant and steam.

Can cause severe injury or death.

Before removing pressure cap stop generator, allow to cool and loosen pressure cap to relieve pressure.

Hot coolant can cause severe injury or death. Allow engine to cool and release pressure from cooling system before opening pressure cap. To release pressure, cover the pressure cap with a thick cloth then turn it slowly counterclockwise to the first stop. After pressure has been completely released and the engine has cooled, remove cap. If generator set is equipped with a coolant recovery tank, check coolant level at tank.

TP-5695 12/93

Safety Precautions and Instructions v

Image 8
Contents Marine Generator Sets Models5CFZ 5CZCalifornia Proposition Table of Contents Safety Precautions and Instructions Carbon monoxide Can cause severe nausea, fainting, or death Carbon monoxide can cause severe nauseaSulfuric acid in batteries Can cause severe injury or death Sulfuric acid in batteries can cause severe injury orExplosive fuel vapors Can cause severe injury or death Explosive fuel vapors can cause severe injury orAccidental starting Can cause severe injury or death Accidental starting can cause severe injury orRotating parts Can cause severe injury or death Flying projectiles can cause severe injury or deathFire Can cause severe injury or death Sudden backfire can cause severe injury or deathSudden flash fire can cause severe injury or death Hazardous noise Can cause loss of hearing246242 Reference Material Pleasure CraftCommercial Vessels Additional ReferencesRoutine Service Parts Part Description Kohler Part NoGlossary of Abbreviations Abbreviation DescriptionNEC Specifications SpecificationsGeneral Specifications IntroductionGenerator 5CFZ/4CZ 5CFZ/6.5CZEngine GX360EVBPR4HS NGK Accessories Service Views Service Views typicalOperation Prestart ChecksController ControllerStarting StoppingEngine Safety Shutdown Switches Circuit ProtectionHigh Water Temperature Shutdown Switch Remote Panel Features Remote Panels OptionalRemote Start and Four-Meter Features Remote Start and Four-Meter Panel KitScheduled Maintenance Service Schedule Or 2 YearsGenerator Specifications Lubrication SystemAdding Oil Oil Change/Oil Filter ChangeFuel System Removing Oil FilterFuel Pump Screen Fuel Pump ScreenCarburetor Adjustments Carburetor/Choke LubricationSpark Plugs Ignition System ServiceIgnition System Problem Means of Identification Possible Cause Normal Gap bridgedOil fouled Carbon fouled12. Checking Spark Plug Gap Hot coolant and steam Can cause severe injury or death Cooling Systems- Closed/Heat ExchangerFilling and Checking 14. Air-Bleed Screw Flushing and Cleaning TP-5695 12/93 Scheduled Maintenance Anticorrosion Zinc 17. Removing Anticorrosion ZincAir Cleaner Mixing Elbow Servicing Air CleanerPressure Cap Servicing Mixing ElbowBattery CleaningChecking Electrolyte Level Checking Specific Gravity21. Specific Gravity Temperature Correction ChargingValve Adjustment 22. Determining Top Dead Center Lubrication Governor AdjustmentGovernor General Generator ServiceWattage Requirements Storage Procedure Troubleshooting EngineUnit cranks but will Not startOperates erratically Problem Possible Cause Corrective Action Stops suddenlyLacks power Electrical System Generator Wiring Diagrams Schematic Wiring Diagram--3.5CFZ, 4CZ, 5CFZ, and 6.5CZDiagrams 4CZTo Load Wire Generator SetsTo Generator To Shore Set Power LO Neutral Ground Load SideLine Side 60 HzL1--L3 Without Jumper LeadPage Motor Loads InstallationGenerator Selection and Wattage Requirements Appliance Loads Kilowatt DeratingTypical Location and Mounting LocationVentilation SpaceMounting Air Requirements CFM L/min Model Combustion CoolingFuel Systems Fuel SupplyAnti-Siphon Provisions Fuel LinesFuel Pump Lift Capabilities Fuel Consumption Max. Lift ft. m In. mmCooling Systems 11. Intake StrainerClosed/Heat Exchanger 13. Seawater StrainerExhaust Systems 15. Closed/Heat Exchanger Cooling System17. Typical Above Waterline Installation Carbon monoxideAbove Waterline Mid/Below WaterlineAC Voltage Connections Installation in Steel or Aluminum VesselsElectrical Systems Battery WiringRemote Start Switch Connection Lead Designations Pin FunctionDimension Drawing--3.5CFZ, 4CZ, 5CFZ, and 6.5CZ SectionSound Shield--Optional on 3.5CFZ and 4CZ Standard on 5CFZ and 6.5CZFor Sales & Service in U.S.A. & Canada Phone Parts Ordering InstructionsOperating Hour Service Log Kohler CO. KOHLER, Wisconsin 53044 Phone