Important: Read complete instructions before beginning installation.

Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and fittings necessary for whirlpool operation. An optional drain/overflow kit is available for installation on the bath.

Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do not lift the bath by the plumbing at any time; handle by the shell only.

Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the finish, do not install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the warranty. Jacuzzi Whirlpool Bath's responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty information packed with the product.

All bath units are factory tested for proper operation and watertight connections prior to shipping. Note: Prior to installation, the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling. Jacuzzi Whirlpool Bath© is not responsible for any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure.

ENGLISH

RECTANGULAR BATHS

L

W

 

2"

(Heater)

(51 mm) H

SIDE VIEW

(Motor)

END VIEW

PLUS BATHS WITHOUT INTEGRAL SKIRT

L

 

(25 mm)

W

 

 

1"

 

(Heater)

 

 

H

SIDE VIEW

(Motor)

 

END VIEW

PLUS BATHS WITH INTEGRAL SKIRT

A

B

DRAIN/OVERFLOW

SPECIFICATIONS (Rectangular)

 

 

 

DRAIN/OVERFLOW

CUTOUT

TOTAL WEIGHT/

OPERATING

PRODUCT

SKIRT &

HEATER

MODEL

 

DIMENSIONS

 

DIMENSIONS

FLOOR LOADING

GALLONAGE

WEIGHT

MOUNTING

 

 

 

 

 

 

 

 

 

 

AMIGA™ PLUS

72"

(1829 mm) L*

16-7/8" (429 mm) A

70" x 34"

772 lb

50 U.S. gal

105 lb

Optional,

Factory Installed

 

36"

( 914 mm) W

14"

(356 mm) B

 

(351 kg)/

(186 liters)

(48 kg)

U-Frame

(S750000 HEATER KIT)

 

 

 

 

43 lb/ft2

 

 

 

 

 

20-3/4" ( 533 mm) H

 

 

 

(210 kg/m2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CETRA© 536

60"

(1524 mm) L*

18-1/2" ( 470 mm) A

NA

742 lb

48 U.S. gal

92 lb

Integral

Factory Installed

PLUS

36"

( 914 mm) W

9"

( 229 mm) B

 

(337 kg)/

(181 liters)

(42 kg)

 

(S750000 HEATER KIT)

WITH INTEGRAL

 

 

 

50 lb/ft2

 

 

 

 

SKIRT

21-1/4" ( 553 mm) H

 

 

 

(244 kg/m2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNA© 5 PLUS

60"

(1524 mm) L*

17-1/2" (445 mm) A

58" x 40"

708 lb

42 U.S. gal

108 lb

Optional,

Factory Installed

 

42"

(1067 mm) W

12-1/2" (318 mm) B

 

(321 kg)/

(159 liters)

(49 kg)

U-Frame

(S750000 HEATER KIT)

 

 

 

 

40 lb/ft2

 

 

 

 

 

22"

( 559 mm) H

 

 

 

(195 kg/m2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNA© 6 PLUS

72"

(1829 mm) L*

16-7/8" (429 mm) A

70" x 40"

826 lb

55 U.S. gal

118 lb

Not

Factory Installed

 

42"

(1067 mm) W

14"

(356 mm) B

 

(375 kg)/

(208 liters)

(54 kg)

Available

(S750000 HEATER KIT)

 

 

 

 

39 lb/ft2

 

 

 

 

 

22"

( 559 mm) H

 

 

 

(190 kg/m2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Add 1/4" to this dimension when roughing-in for 3-wall niche.

NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4".

FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.

RapidHeatTM: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.

Motor/Pump: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.

1

Jacuzzi Whirlpool Bath© BP43000 2/05

Image 7
Contents COMFORT PLUS BATH SERIES INSTALLATION AND OPERATING INSTRUCTIONSENGLISH PRECAUTIONS OPERATING INSTRUCTIONS Safety Instructions ChangeADDENDUM SHOCK, OR INJURY TO PERSONSPRECAUTIONS INSTALLATION INSTRUCTIONSSave These Instructions for Future Use CONTENTSOwners Record PLUS BATHS WITHOUT INTEGRAL SKIRT SPECIFICATIONSSPECIFICATIONS Rectangular RECTANGULAR BATHSCORNER BATHS SPECIFICATIONS OvalSPECIFICATIONS Corner RIMLESS OVAL BATHSCUTOUT- CORNER BATH Corner Baths with SkirtROUGHING-INREFERENCE RECTANGULAR ROUGHING-INREFERENCE OVAL AND CORNERSEMI-SUNKEN Framing and SupportTYPICAL INSTALLATIONS FLUSH TO WALLU FRAME SKIRT MOUNTING DETAIL SkirtsRemovable Skirt Panel INTEGRAL SKIRT MOUNTING DETAILService Access with Integral Skirt Service AccessRapidHeatTM Service Access Service Access with SkirtELECTRICAL CONNECTION WITH RAPIDHEAT Electrical ConnectionsELECTRICAL CONNECTION FOR CORNER BATHS Plumbing Clean-UpAfter InstallationPlumbing and Water Supply Drain InformationComfort Plus With Light System OPERATING INSTRUCTIONSControl Panel OperationHigh-LimitSwitch Controlling Whirlpool ActionRapidHeatTM Operation Vacuum SwitchRepairs to the Surface MAINTENANCE INSTRUCTIONSCleaning the Bath Suction Cover/Strainer MaintenanceREMEDY General Whirlpool Bath Troubleshooting GuidePROBLEM PROBABLE CAUSESJacuzzi Whirlpool Bath Service Support: 800Authorized Service AUTHORIZED SERVICE AUTHORIZED SERVICE ChangeP.O. Box 702168 Dallas, TX Jacuzzi Whirlpool Bath Limited WarrantyComfort Plus Bath Product Jacuzzi Whirlpool BathRESPONSIBILITIES OF OTHERS WARRANTY SERVICEESPAÑOL SERIE DE TINAS COMFORT PLUSMANUAL DE INSTALACION Y OPERACION Instalador: Deje este manual al propietarioINSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONESLEA Y SIGA TODAS LAS INSTRUCCIONES PRECAUCIONES OPERAR INSTRUCCIONES Las Instrucciones de la seguridad Cambian06/05 INSTRUCCIONES INSTRUCCIONESPRECAUCIONES 2005 Jacuzzi Whirlpool Bath DA38000AConserve estas instrucciones para uso futuro TABLA DE CONTENIDORegistro del propietario BAÑERAS CON FALDON INTEGRADO ESPECIFICACIONESBAÑERAS RECTANGULARES BAÑERAS SIN FALDON INTEGRADOESPECIFICACIONES de esquina BAÑERAS DE OVALADASESPECIFICACIONES Ovaladas BAÑERAS DE ESQUINASOPORTE PARA TINAS DE ESQUINA Tinas de Esquina con FaldónDIAGRAMAS EN PLANTA DE INSTALACIONES RECTANGULAR DIAGRAMA EN PLANTA DE TINAS DE ESQUINADETALLE DEL MONTAJE DE PESTAÑA TIPICO INSTALACIONEstructura y soporte INSTALACIONES TÍPICASDETALLE DEL MONTAJE CON FALDÓN INTEGRADO INSTALACION FALDÓNEntrepaño movible de falda DETALLE DEL MONTAJE CON FALDÓN EN “U”RapidHeatTM Acceso para servicio INSTALACIONAcceso de servicio bañera con faldón Acceso opcional de servicio deConexiones eléctricas INSTALACIONLimpieza después de la instalación Información sobre el desagüePlomería Suministro de aguaDespliegue LED OPERACIÓNFUNCIONAMIENTOControle Entrepaño ON/OFF Bombea/MotorCONTROLES PARA INDUCCIÓN DE AGUA Cómo controlar el sistema de hidromasajeNivel del Agua CHORROSPurgar el sistema de las bañeras de hidromasaje MANTENIMIENTOCómo limpiar la bañera Reparaciones de la superficiera. Vuelva a colocar la cobertura de PROBLEMAPROBABLES CAUSAS SOLUCIÓNLAS ESPECIFICACIONES DEL PRODUCTO ESTAN SUJETAS A CAMBIOS SIN PREVIA NOTIFICACION Productos para el Baño y la Ducha Servicios autorizadosAFC.PDF Cambio AUTORIZADO de SERVICIOServicios autorizados productos para el baño y la duchaLIMITACIONES DE LA GARANTÍA Producto de Grupo de Tinas Comfort PlusCOBERTURA DE LA GARANTÍA GARANTÍA LIMITADA DE UN AÑO EN LAS TINASRESPONSABILIDAD DE TERCEROS TARJETA DE REGISTRO PARA LA GARANTÍA