Electrical Connections
Two separate 120 VAC, 15 AMP circuits, which must be protected by a Ground Fault Circuit Interrupter (GFCI), are required. Install duplex outlets to the studwall underneath the bathtub, at least 4 inches above the floor. The duplex outlets are not provided. One circuit is for the pump/motor and the other is for the RapidHeatTM heater.
Install a separate 120 VAC, 15 AMP dedicated circuit with GFCI protection. With a #8 solid copper wire, bond the heater to the house electrical panel or approved local bond. A bonding lug is provided on the heater.
At initial
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Interrupter.
CAUTION: Operating the motor/pump without enough water in the bath can cause leaking and permanent damage to the pump and/ or heater. Before power is applied to the installation, make sure the switch is in the OFF position to avoid pump damage.