Bryant 558F manuals
Household Appliance > Air Conditioner
When we buy new device such as Bryant 558F we often through away most of the documentation but the warranty.
Very often issues with Bryant 558F begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Bryant 558F is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
170 pages 4.98 Mb
Form No. PDS 558F.36.2 COMMERCIAL SINGLE PACKAGE ROOFTOP ELECTRIC COOLING UNITS 551A, 551B, 558F, 559F DuraPac and DuraPac Plus Series
Also you can find more Bryant manuals or manuals for other Household Appliance.
Bryant 558F Installation Instructions
70 pages 2.03 Mb
installation, start-up and service instructionsSINGLE PACKAGE ROOFTOP ELECTRIC HEATING/ELECTRIC COOLING UNITS 558FPacDura SeriesSizes 090-151 71/ to 121/3 Fig. 2 Roof Curb Details7 Table 1A Physical Data 558F090,102,120,150 Units8 Table 1B Physical Data 558F091,103,121,151 Units(ASHRAE 90.1-1999 Compliant Units) 10 Table 2A Electrical Data (Units Without Convenience Outlet) (558F090, 102, 120, 150)12 Table 2A Electrical Data (Units Without Convenience Outlet) (558F090, 102, 120, 150) (cont)13 Table 2B Electrical Data (Units Without Convenience Outlet) (558F091, 103, 121, 151)14 Table 2B Electrical Data (Units Without Convenience Outlet) (558F091, 103, 121, 151) (cont)15 Table 2B Electrical Data (Units Without Convenience Outlet) (558F091, 103, 121, 151) (cont)16 Table 2C Electrical Data (Units With Convenience Outlet) (558F090, 102, 120, 150)18 Table 2C Electrical Data (Units With Convenience Outlet) (558F090, 102, 120, 150) (cont)19 Table 2D Electrical Data (Units With Convenience Outlet) (558F091, 103, 121, 151)21 Table 2D Electrical Data (Units With Convenience Outlet) (558F091, 103, 121, 151) (cont)24 HoodBox27 D C B ATR1 0ENTHALPYBTU PER POUND DRY AIR D C B A APPROXIMATE DRY BULB TEMPERATURE F (C) 2345678 5000 4000 3000 2000 1000+_ 12 34 5 EF EF1 P1 T1 P T N N1 6000800ppm 900ppm 1000ppm 1100ppm RANGE CONFIGURATION (ppm) DAMPER VOLTAGE FOR MAX VENTILATION RATE CO SENSOR MAX RANGE SETTING 2 28 Fig. 31 Enthalpy Changeover Set PointsFig. 33 CO2 Sensor Maximum Range Setting Fig. 32 EconoMi$er IV Control 32 Table 6 Fan Rpm at Motor Pulley Settings*Table 7 Evaporator-Fan Motor Efficiency Table 8 Accessory/FIOP Static Pressure* (in. wg) 33 Table 9 Evaporator Fan Motor DataGENERAL FAN PERFORMANCE NOTES 34 Table 10 Fan Performance 558F090,091 Vertical Discharge Units; Standard Motor (Belt Drive)*35 Table 11 Fan Performance 558F090,091 Vertical Discharge Units; Alternate Motor (Belt Drive)*36 Table 12 Fan Performance 558F090,091 Vertical Discharge Units; High-Static Motor (Belt Drive)*37 Table 13 Fan Performance 558F102,103 Vertical Discharge Units; Standard Motor (Belt Drive)*38 Table 14 Fan Performance 558F102,103 Vertical Discharge Units; High-Static Motor (Belt Drive)*39 Table 15 Fan Performance 558F120,121 Vertical Discharge Units; Standard Motor (Belt Drive)*40 Table 16 Fan Performance 558F120,121 Vertical Discharge Units; Alternate Motor (Belt Drive)*41 Table 17 Fan Performance 558F120,121 Vertical Discharge Units; High-Static Motor (Belt Drive)*42 Table 18 Fan Performance 558F150,151 Vertical Discharge Units; Standard Motor (Belt Drive)*43 Table 19 Fan Performance 558F150,151 Vertical Discharge Units; Alternate Motor (Belt Drive)*44 Table 20 Fan Performance 558F090,091 Horizontal Discharge Units; Standard Motor (Belt Drive)*45 Table 21 Fan Performance 558F090,091 Horizontal Discharge Units; Alternate Motor (Belt Drive)*46 Table 22 Fan Performance 558F090,091 Horizontal Discharge Units; High-Static Motor (Belt Drive)*47 Table 23 Fan Performance 558F102,103 Horizontal Discharge Units; Standard Motor (Belt Drive)*48 Table 24 Fan Performance 558F102,103 Horizontal Discharge Units; High-Static Motor (Belt Drive)*49 Table 25 Fan Performance 558F120,121 Horizontal Discharge Units; Standard Motor (Belt Drive)*50 Table 26 Fan Performance 558F120,121 Horizontal Discharge Units; Alternate Motor (Belt Drive)*51 Table 27 Fan Performance 558F120,121 Horizontal Discharge Units; High-Static Motor (Belt Drive)*52 Table 28 Fan Performance 558F150,151 Horizontal Discharge Units; Standard Motor (Belt Drive)*53 Table 29 Fan Performance 558F150,151 Horizontal Discharge Units; Alternate Motor (Belt Drive)*63 Fig. 49 Typical Unit Wiring Schematic64 Table 30 Cooling Service Analysis65 Table 31 EconoMi$er IV Input/Output LogicFig. 50 EconoMi$er IV Functional View
Also you can find more Bryant manuals or manuals for other Household Appliance.