Sanyo SAP-CMRV1926EH manuals
Household Appliance > Air Conditioner
When we buy new device such as Sanyo SAP-CMRV1926EH we often through away most of the documentation but the warranty.
Very often issues with Sanyo SAP-CMRV1926EH begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Air Conditioner Sanyo SAP-CMRV1926EH is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Air Conditioner on our side using links below.
Sanyo SAP-CMRV1926EH Service Manual
148 pages 6.28 Mb
TECHNICAL & SERVICE MANUALOUTDOOR UNIT : SAP-CMRV1426EH SAP-CMRV1926EH SAP-CMRV1936EH SAP-CMRV2446EH SAP-CMRV3146EHF-GAS REGULATION (EC) No 842 / 2006 SAP-CMRV3146EH SAP-CMRV1426EH SAP-CMRV1926EH SAP-CMRV1936EH SAP-CMRV2446EH DC INVERTER MULTI-SYSTEM AIR CONDITIONER 4 ()5 APPLICABLE INDOOR UNITS6 1. OPERATING RANGE7 2. SPECIFICATIONS18 3. DIMENSIONAL DATA23 4. REFRIGERANT FLOW DIAGRAM4-1. Refrigerant Flow Diagram 28 5. PERFORMANCE DATA59 6. ELECTRICAL DATA6-1. Electric Wiring Diagrams 64 7. FUNCTIONS71 8. TROUBLESHOOTING78 9. REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN SERVICING UNIT82 NO!83 9-6. In Case Refrigerant is Leaking84 9-7. Charging Additional Refrigerant9-8. Retro-Fitting Existing Systems 86 INSTALLATION INSTRUCTIONS In ver ter Multi Split System Air Conditioner Espaol Franais Deutsch Italiano Portugus EEThis air conditioner uses the new refrigerant R410A. For Outdoor Unit 87 IMPORTANT! 91 NO107 INSTALLATION INSTRUCTIONS In ver ter Multi Split System Air Conditioner Espaol Franais Deutsch Italiano Portugus EEThis air conditioner uses the new refrigerant R410A. For Outdoor Unit 108 IMPORTANT! 116 NO117 (2) SAP-CMRV1936(3) SAP-CMRV2446 Fig. 6c (4) SAP-CMRV3146 2-4. Outer Dimensions of Outdoor Unit Fig. 6a Fig. 6b Fig. 6d (1) SAP-CMRV1926 118 2-5. Diagram of Outdoor Unit Installation Never install only a single indoor unit.Fig. 6e 119 3. Installation Process120 CD 122 4. Air Purging(for Test Run) C D 125 5. Wiring InstructionsGBe sure to comply with local codes on running 08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 20 126 the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.).Fig. 25a Fig. 25cUNIT A UNIT B UNIT C UNIT D GEach wire must be firmly connected. GNo wire should be allowed to touch refrigerant 5-3. Wiring System Diagram 3 indoor units with SAP-CMRV1936 Fig. 25b tubing, the compressor, or any moving part.GBe sure to connect power wires correctly matching up numbers on terminals of the outdoor unit and respective indoor units A D.GBe sure to connect the power supply line to the outdoor unit as shown in the wiring diagram. The indoor unit draws its power from the outdoor unit.GDo not run wiring for antenna, signal, or power GTo avoid the risk of electric shock, each air conditioner unit must be grounded.GFor the installation of a grounding device, please observe local electrical codes.GGrounding is necessary, especially for units GPlace a dedicated ground more than 2 meters away from other grounds and do not have it shared with other electric appliances. 4 indoor units with SAP-CMRV2446, CMRV3146UNIT A L N UNIT B UNIT C L N UNIT B 2 indoor units with SAP-CMRV1926 128 Indoor unit DIndoor unit B Indoor unit C Indoor unit A Outdoor unit 5-5. Wiring Instructions for the Outdoor Unit inspection panel and tubing panel. contact with tubing or service valves. inter-unit cables at the location where the cables are double-sheathed. contained in the inspection panel and tubing panel, as shown in Fig. 31. 129 6. Test Run130 7. Connecting a Home Automation Device08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 24 Fig. 33a 8. Installation Check Sheet SAP-KMRV74/94/124EH8FA-2-5257-72600-1EVAPORATOR CONTROLLERGRN/YEL E YEL BLU 4P(WHT) FAN MOTOR TERMINAL BASE FERRITE CORE FLAP PNK BLU BRN YEL IND LAMP ASSY TO OUTDOOR UNIT SI-2 SI AC IN AC IN-2 FLAP 5P(WHT) LAMP FLAP MOTOR CONNECTOR 9P(WHT) UV ASSY HA JEM-A DCM 6P(BLU) FM ROOM/COIL/UV 6P(WHT) ROOM THERMISTOR COIL THERMISTOR ORG ORG GRN/YEL ION ASSY FLAP CONNECTOR FLAP MOTOR PNK BLU BRN YEL IND LAMP ASSYROOM/COIL 4P(WHT) DCM 6P(BLU) FM FAN MOTOR RED YEL BLU GRN/YEL ROOM THERMISTOR COIL THERMISTORION 3P(WHT) HA JEM-A 4P(WHT) 1 2 4 1 2 34 1 2 34 ION TERMINAL TERMINAL BASE EVAPORATOR YEL/GRN TO OUTDOOR UNIT 131 SAP-KRV184/244EH08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 25 SAP-KRV96/126EHDS SAP-KMRV76/96/126EH Fig. 33b SAP-KRV186/246EH Fig. 33c8FA-2-5250-27700-1 8FA-2-5250-07400-1 Fig. 33d Fig. 33e 132 Fig. 34b08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 26 SAP-CMRV1936EH Fig. 34a MV3 8FA-2-5257-57100-0 133 Fig. 34c08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 27 Fig. 34d SAP-CMRV2446EH SAP-CMRV3146EH 134 English Espaol FranaisDeutsch08-253 CMRV3146EH_OU EN 10/14/08 2:39 PM Page 28 Bedeutung der AbkrzungenSignificado das abreviaturas Significato delle abbreviazioni Meaning of Abbreviations Significado de las abreviaturas Italiano PortugusESignification des abrviations E 135 UNIT COMBINATION TABLESAPPENDIX C136 2-Room Outdoor Unit Combination Table138 2-Room Outdoor Unit Combination Table5.6 x 2 5.15 + 5.15 11.2 10.3 < Combinations of operatable indoor units > SAP-CMRV1924EH (Rated cooling capacity: 5.6 kW) 139 SAP-CMRV1926EH2.2: SAP-KMRV74/76EH 2.65: SAP-KMRV94/96EH 3.5: SAP-KMRV124/126EH 5.15: SAP-KRV184/186EH SAP-CMRV1936EH 140 3-Room Outdoor Unit Combination Table5.6 x 2 2.2 + 3.5 + 5.15 11.2 10.85 < Combinations of operatable indoor units > SAP-CMRV1934EH (Rated cooling capacity: 5.6 kW) 141 SAP-CMRV1936EH 2.2: SAP-KMRV74/76EH 2.65: SAP-KMRV94/96EH 3.5: SAP-KMRV124/126EH 5.15: SAP-KRV184/186EH 2.65: SAP-KRV96EHDS 3.5: SAP-KRV126EHDS SAP-CMRV2446EH 142 4-Room Outdoor Unit Combination Table6.8 x 2 2.2 + 2.65 + 3.5 + 5.15 13.6 13.5CombinationTable-2446EH.fm Page 2 Friday, September 26, 2008 10:20 AM Table 1 < Combinations of operatable indoor units > SAP-CMRV2444EH (Rated cooling capacity: 6.8 kW) 2.65: SAP-KMRV94EH 3.5: SAP-KMRV124EH 5.15: SAP-KRV184EH 7.1: SAP-KRV244EH 2 143 SAP-CMR V2446EH Table 2CombinationTable-2446EH.fm Page 3 Friday, September 26, 2008 10:20 AM 144 32.65: SAP-KRV96EHDS 3.5: SAP-KRV126EHDS SAP-CMRV3146EH 145 4-Room Outdoor Unit Combination Table8 x 2 2.2 + 2.2 + 3.5 + 7.1 16 15CombinationTable-3146EH.fm Page 2 Friday, September 26, 2008 10:31 AM Table 1 2 < Combinations of operatable indoor units > (Rated cooling capacity: 8.0 kW) 146 SAP-CMR V3146EH Table 2CombinationTable-3146EH.fm Page 3 Friday, September 26, 2008 10:31 AM 147 32.65: SAP-KRV96EHDS 3.5: SAP-KRV126EHDS
Also you can find more Sanyo manuals or manuals for other Household Appliance.