SAP-KMRV76/96/126EH

 

 

 

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FERRITE CORE

 

TERMINAL BASE

 

 

 

GRN/YEL

 

 

 

 

 

 

 

 

 

TO OUTDOOR

 

 

 

 

 

 

 

 

 

 

 

BLK

 

1

 

 

 

 

 

 

 

 

 

 

 

 

WHT

2

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

English

FLAP MOTOR

 

 

 

AC IN

 

 

SI-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

RED

1

1

AC IN-2

SI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

PNK

2

2

FLAP

 

 

 

 

 

 

 

 

 

FLAP

3

3

BLU

3

3

5P(WHT)

 

 

1

1

RED

1

1

 

 

4

4

BRN

4

4

 

 

 

 

2

2

WHT

2

2

IND LAMP ASS

 

5

5

YEL

5

5

 

 

 

 

3

3

WHT

3

3

CONNECTOR

 

 

 

 

 

LAMP

4

4

WHT

4

4

 

 

 

 

 

9P(WHT) 5

5

WHT

5

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

6

WHT

6

6

 

 

 

 

 

 

 

 

 

 

7

7

WHT

7

7

 

 

 

 

 

 

 

CONTROLLER

8

8

WHT

8

8

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

9

WHT

9

9

 

 

FAN MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

 

 

 

 

 

 

 

 

 

 

 

FM

 

 

BLK

3

3

DCM

 

 

 

 

 

 

 

 

 

 

 

 

WHT

4

4

6P(BLU)

 

 

 

 

 

 

 

UV ASSY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

5

5

 

 

 

 

 

 

 

ROOM THERMISTOR

 

 

 

 

BLU

6

6

 

 

 

 

1

1

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM/COIL/UV

2

2

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

6P(WHT)

3

3

ORG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

4

ORG

 

 

 

 

 

 

 

 

 

 

 

HA

 

5

5

RED COIL THERMISTOR

 

 

 

 

GRN/YEL

 

 

E

JEM-A

 

6

6

BLK

 

 

 

 

 

 

 

 

 

 

4P(WHT)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 33b

 

 

8FA-2-5250-29700-2

 

 

 

 

 

 

 

 

 

 

 

 

 

SAP-KRV96/126EHDS

 

 

 

 

 

 

 

TO OUTDOOR

 

 

1 2

+

BASE

TERMINAL

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

+

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

+

+

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVAPORATOR

EARTH PLATE

 

BRN

RED

ORG

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLAP MOTOR

 

 

 

 

7 5 3 1

 

 

 

 

 

 

 

 

 

 

 

 

7 5 3 1

 

 

 

 

 

 

 

 

(UPPER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELEC-JB1 (WHT)

 

 

 

 

 

 

 

 

 

 

1 2 3 4 1 2 3 4

 

WHT

1 2 3 4

1 2 3 4

 

 

UV (RED)

1 2

1 2

RED

1 1

RED

UV UNIT

 

 

 

 

 

 

FLAP1

 

GRY

 

 

BLK

2 2

BLK

 

 

 

 

 

 

GRY

 

 

 

(RED)

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4

1 2 3 4

BLK

 

 

THERMISTOR

 

5 5

 

GRY

5 6 7 8

5 6 7 8

FLAP1 (WHT)

 

 

 

ROOM /COIL (WHT)

 

 

 

 

 

 

 

 

BLK

 

 

(ROOM)

(WHT) (WHT)

WHT

 

 

 

 

 

 

 

 

ORG

 

 

THERMISTOR

 

 

 

BLU

 

 

 

 

 

 

1 1

 

 

 

 

ORG

 

 

(COIL)

 

FLAP2

 

BLU

 

 

 

 

 

 

2 3 4 2 3 4

 

BLU

9 10

9 10

 

 

 

 

HUM (RED)

1 2

1 2

BLK

 

 

THERMISTOR

 

BLU

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

(HUM)

 

 

 

 

 

 

 

 

 

 

 

5 5

 

 

 

1 2 3 4

 

 

 

 

SW2 (BLU)

1 2

1 2

WHT

 

 

 

 

(WHT) (RED)

 

 

HA JEM-A (WHT)

 

 

 

PANEL SW

 

 

 

BLK

 

 

FLAP MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(LOWER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1

WHT

1 1

 

 

PANEL MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER

 

2 2

GRY

2 2

 

 

 

1 1

WHT

1 2 3 4 5

1 2 3 4 5

 

 

 

3 4 5 6 7 8 9

3 4 5 6 7 8 9

GRY

3 4 5 6 7 8 9

3 4 5 6 7 8 9

 

 

 

 

 

 

 

IND LAMP ASSY

 

FLAP3

2 2

GRY

PANEL (WHT)

 

LAMP (WHT)

GRY

 

 

 

 

3 3

GRY

 

GRY

 

4 4

GRY

 

GRY

 

 

 

 

5 5

GRY

 

GRY

 

(WHT)

 

 

 

GRY

 

 

 

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

10

10

10

10

 

 

 

 

 

 

 

 

 

 

 

 

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(WHT)

 

 

 

DC FAN MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

1 1

RED

1 1

 

 

 

 

 

1 1

WHT

1 1

S

 

 

 

2 3 4 5 6 2 3 4 5 6

 

2 3 4 5 6

2 3 4 5 6

DCM (BLU)

 

 

 

SW1 (WHT)

2 3 4 5

2 3 4 5

BLU

2

2 3 4 5

W ASSY

 

 

 

 

 

 

 

 

 

FM

BLK

BLK

 

 

 

BLU

3

 

 

 

 

 

 

WHT

WHT

 

DC OUT (WHT)

BLU

4

 

 

 

 

YEL

YEL

 

BLU

5

 

BLU

BLU

 

(WHT)

 

 

 

 

 

 

 

 

 

(BLU)

 

 

 

 

 

3 2 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 33c

 

 

8FA-2-5250-07400-1

 

 

 

 

 

 

 

 

 

 

 

 

Electric wiring diagram for 2-room multi outdoor unit (CMRV1426EH)

COMPRESSOR THERMISTOR

BLK BLK

WHT

11 BLK

22 BLK

(2P) CONNECTOR

RED

COIL

THERMISTOR

YEL

YEL

BLK

BLK OUTDOOR THERMISTOR

CONNECTOR

AW THERMISTOR

CONNECTOR

WHT

1

2

3

4

RED

 

 

 

 

 

 

1

2

3

4

 

 

(4P)

 

YEL

YEL

BLK

BLK

(4P)

 

1 2 3 4 COIL/OUTDOOR

1

2 COMP

w

YEL

YEL

YEL

YEL

1

2

3

4

1

2

3

4

YEL

YEL

YEL

YEL

1

2

3

4

A-TH

THERMISTOR

THERMISTOR

AN

BW

CONNECTOR

BLU

(4P)

 

 

 

 

TOR

 

COIL

 

COIL

REACTANCE

 

 

 

 

 

 

 

 

THERMIS

DEFROST VALVE

4WAY VALVE

 

 

 

 

 

 

 

 

 

 

 

 

DEF

 

RV

 

 

 

 

 

 

 

 

YEL

YEL

YEL

YEL BN

(2P)CONNECTOR

BLU

BLU

(2P)CONNECTOR

BLU

BLU

(2P)CONNECTOR

WHT

WHT

GRN/YEL

GRN/YEL

GRN/YEL

 

 

YEL

YEL

YEL

YEL

BLK BLK

BLK

WHT BLK

BLK

WHT WHT

WHT

 

 

1

2

3

4

 

2

1

 

2

1

 

2

1

 

 

 

 

 

 

2

1

 

2

1

 

2

1

 

 

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

w

w

 

w

w

 

w

w

w

w

w

w

BLK

 

B-TH

 

 

 

 

 

 

 

DEF1 DEF0

 

RV1

RV0

 

L2

L1

E-2

E-1

E

ACIN1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25A

w

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACIN2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER

TERMINAL

PLATE

WHT 1 1 WHT WHT 2 2 WHT

OLR0

w OLR1

S1-A w RED

1

INDOOR

 

(2P) CONNECTOR

(OLR)

OVERLOAD RELAY

U V W w w w

CN04 DCFM

1

2

3

4

5

6

7

MV1

1

2

3

4

5

 

MV0

 

 

1

2

3

4

5

S1-B w BLU

2

UNIT

UNIT

3

A

 

BLK

 

 

COMPRESSOR

 

(3P) CONNECTOR

MOTOR

 

RED(PNK)

1

1

RED(PNK)

C

WHT

 

2

2

WHT

CM

 

R

BLU

 

3

3

BLU

S

 

 

FERRITE

WHT

 

 

 

 

GRN/YEL

CORE

 

 

 

 

 

 

 

(7P) CONNECTOR

 

WHT

 

 

BLK

 

RED

 

BLU

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

 

6

 

7

 

 

1

2

3

4

 

5

 

6

 

7

 

 

WHT

 

 

BLK

 

RED

 

BLU

 

YEL

 

FM

FAN MOTOR

WHT

CONNECTOR

 

(5P)

ORG

RED

YEL

BLK

GRY

1

2

3

4

5

1

2

3

4

5

ORG

RED

YEL

BLK

GRY

1

2

3

4

5

1

2

3

4

5

MV1

BLU

CONNECTOR

 

ORG

 

RED

 

YEL

 

BLK

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

1

 

2

 

3

 

4

 

5

 

 

1

 

2

 

3

 

4

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5P)

ORG

 

RED

 

YEL

 

BLK

 

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

 

3

 

4

 

5

 

 

 

 

1

 

2

 

3

 

4

 

5

 

 

MV0

REACTANCE

BLK

BLK

 

4

 

INDOOR UNIT

INDOORTO

WHT

5

 

 

6

 

 

 

B

 

 

7

N L

POWER SUPPLY

 

WHT

8

 

 

 

 

 

 

GND

 

MAGNETIC COIL

MAGNETIC COIL

Fig. 34

WARNING

To prevent electric shock, do not inspect or repair until the Power Lamp on the P.C.Board is turned off.

8FA-2-5257-56900-2

Meaning of Abbreviations

 

ABBREV.

MEANING

 

 

 

1

BLK

BLACK

 

 

 

2

BLU

BLUE

 

 

 

3

BRN

BROWN

 

 

 

4

GRN/YEL

GREEN/YELLOW

 

 

 

5

GRY

GREY

 

 

 

6

ORG

ORANGE

 

 

 

7

PNK

PINK

 

 

 

8

RED

RED

 

 

 

9

VLT

VIOLET

 

 

 

10

WHT

WHITE

 

 

 

11

YEL

YELLOW

 

 

 

20

Page 105
Image 105
Sanyo SAP-CMRV1926EH, SAP-CMRV1426EH-F service manual SAP-KMRV76/96/126EH, Controller

SAP-CMRV1926EH, SAP-CMRV1426EH-F specifications

The Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F stand out in the realm of advanced climate control solutions. As part of Sanyo's renowned lineup of air conditioning systems, these models are designed to offer superior performance, energy efficiency, and enhanced comfort, catering to both residential and commercial use.

One of the main features of the SAP-CMRV1926EH is its robust cooling and heating capacity, making it an ideal choice for larger spaces or those requiring rapid temperature adjustments. The model boasts a cooling capacity of up to 19kW, while the SAP-CMRV1426EH-F offers a more compact 14kW, making it suitable for smaller environments without compromising performance. This flexibility allows users to select a model that best fits their specific needs.

Both models incorporate advanced inverter technology, which significantly enhances their energy efficiency. By adjusting the compressor speed according to the ambient temperature, inverter systems minimize power consumption while maintaining a stable indoor climate. This not only reduces electricity bills but also contributes to a lower environmental impact, aligning with modern sustainability standards.

In terms of comfort, the Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F feature sophisticated air distribution systems. They ensure even airflow throughout the area, eliminating hotspots and providing consistent temperatures. Additionally, the models are equipped with multi-split capabilities, allowing for multiple indoor units to be connected to a single outdoor unit. This versatility is particularly beneficial for larger buildings or homes with varied room requirements.

Both models also prioritize user convenience with sophisticated control options. They offer wireless remote controls as well as compatibility with smart home systems, enabling users to program settings and monitor indoor conditions from their smartphones or tablets. This modern approach enhances user engagement and allows for greater customization of the climate control experience.

Noise levels are another consideration in the design of the SAP-CMRV1926EH and SAP-CMRV1426EH-F. These units operate quietly, ensuring that they do not disrupt the tranquility of living or working spaces. Their low-noise operation is a testament to Sanyo's commitment to creating comfortable environments without compromising on performance.

In summary, the Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F models are distinguished by their impressive cooling and heating capacities, energy-efficient inverter technology, advanced air distribution, user-friendly controls, and quiet operation. These features make them an excellent choice for anyone seeking reliable and effective climate control solutions.