Outdoor Unit SAP-CMRV1936EH

To avoid electrical shock hazard, be sure to WARNING disconnect power before checking, servicing

and/or cleaning any electrical parts.

 

SUPPLY

 

UNIT INDDOR TO

 

 

TERMINAL

GND

UNIT

UNIT

UNIT

9

GND

1

2 3

1 2 3 4 5 6

7 8

 

POWER

 

A INDDOR

B INDDOR

C INDDOR

 

PLATE

L

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

BLK WHT

WHT

 

 

CORE

FERRITE

 

BLK

 

WHT

 

RED

 

BLU

BLK BLK

REACTANCE

CONNECTOR 1 2

GRN/YEL

GRN/YEL

GRN/YEL

WHT

1 1

WHT

WHT

2 2

WHT

WHT

CONNECTOR (2P)

WHT

WHT

W WW W W W W W HEATER1 HEATER0 L2 L1 E-2 E-1 E ACIN1

W 25A ACIN2

W

W

SI-A

SI-B

5 5

4 4

3 3

MV0

2 2

1 1

5 5

4 4

3 3

MV1

2 2

1 1

REACTANCE

GRY

45 4

 

COIL

 

5

 

 

BLK

21 1

MV0

MAGNETIC

ORG

YEL

3 3

 

 

RED

2

 

 

 

 

 

GRY

45 4

 

COIL

 

5

 

 

BLK

21 1

MV1

MAGNETIC

ORG

YEL

3 3

 

 

RED

2

 

 

 

 

 

BRN

WHT 1 2

(2P)

 

VALVE

 

COIL

RV

4WAY

 

 

 

 

 

 

CRANKCASE

WHT

 

 

 

 

 

HEATER

WHT

 

 

 

 

 

 

BLU

1 1

BLK

W RV0

2 2

W RV1

BLU

BLK

 

WHT

 

 

CONNECTOR (2P)

 

W

SICOM2

4

3

KS10 2

1

WHT

W SICOM2

SI-C W

 

 

BLU

4 4

5 5

RED

3

4 4

WHT

23 2 CN01

MV2

1 1

3 3

BLK

2 2

 

 

1 1

GRY

45 4

 

COIL

 

5

 

 

BLK

21 1

MV2

MAGNETIC

ORG

YEL

3 3

 

 

RED

2

 

 

 

 

 

VALVE

DEF

COIL

DEFROST

BLU

1 1

BLK

BLU

2 2

BLK

BLK

 

CONNECTOR (2P)

THERMISTOR BN

 

YEL

 

YEL

 

YEL

 

YEL

THERMISTOR BW

THERMISTOR AN

 

YEL

 

YEL

 

YEL

 

YEL

THERMISTOR AW

THERMISTOR

 

OUTDOOR

BLK

 

BLK

 

YEL

 

YEL

THERMISTOR

COI

L

DEF1 DEF0

W W

4 4

3 3 TH

2 2 B-

1 1

4 4

3 3 TH

2 2 A-

1 1

21 1 COIL/OUTDOOR

 

4 4

 

3 3

 

2

 

 

COMP

1 1 2 2

CONTROLLER

321

 

6

 

5

 

4

 

KS22

8

7

6

5

KS23 4

3

2

1

 

 

 

7

 

 

 

6

 

 

 

DCFM

 

 

 

5

 

 

 

4

 

 

 

CN04

OLR0

OLR1

 

3

U V W

1 2

W

W

W W W

 

WHT

6 6

5 5

BLK

4

BLU

34 3 CN02

RED

WHT

2 2

1 1

BLK

 

BLU

8 8

7 7

RED

6 6

WHT

5

BLK

45 4 CN03

BLU

RED

3 3

2 2

WHT

1 1

BLK

 

ORG

7 7

6 6

WHT

5 5

BRN

4 4

BLU

3 3

 

 

2 2

RED

1 1

 

CORE

 

4 4

3

TH 3

C- 2 2

1 1

ORG

WHT

BRN

BLU

RED

THERMISTOR CN

YEL

YEL

YEL

YEL

THERMISTOR CW

FM FAN MOTOR

RELAY

 

(OLR)

 

OVERLOAD

WHT WHT

GRN/YEL

 

 

FERRITE WHT

RED 2 1 CONNECTOR

BLK BLK

BLU WHT (PNK) RED

3 3

 

2 2

 

1 1

(PNK)

 

BLU

 

CM

WHT

R/ V

RED

 

S/U

 

MOTOR

1

COMPRESSOR

WHT 2 WHT (2P)

THERMISTOR COMPRESSOR

CONNECTOR (3P)

8FA2-5257-57000-0

61

Page 61
Image 61
Sanyo SAP-CMRV1926EH, SAP-CMRV1426EH-F service manual Supply Unit Inddor to

SAP-CMRV1926EH, SAP-CMRV1426EH-F specifications

The Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F stand out in the realm of advanced climate control solutions. As part of Sanyo's renowned lineup of air conditioning systems, these models are designed to offer superior performance, energy efficiency, and enhanced comfort, catering to both residential and commercial use.

One of the main features of the SAP-CMRV1926EH is its robust cooling and heating capacity, making it an ideal choice for larger spaces or those requiring rapid temperature adjustments. The model boasts a cooling capacity of up to 19kW, while the SAP-CMRV1426EH-F offers a more compact 14kW, making it suitable for smaller environments without compromising performance. This flexibility allows users to select a model that best fits their specific needs.

Both models incorporate advanced inverter technology, which significantly enhances their energy efficiency. By adjusting the compressor speed according to the ambient temperature, inverter systems minimize power consumption while maintaining a stable indoor climate. This not only reduces electricity bills but also contributes to a lower environmental impact, aligning with modern sustainability standards.

In terms of comfort, the Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F feature sophisticated air distribution systems. They ensure even airflow throughout the area, eliminating hotspots and providing consistent temperatures. Additionally, the models are equipped with multi-split capabilities, allowing for multiple indoor units to be connected to a single outdoor unit. This versatility is particularly beneficial for larger buildings or homes with varied room requirements.

Both models also prioritize user convenience with sophisticated control options. They offer wireless remote controls as well as compatibility with smart home systems, enabling users to program settings and monitor indoor conditions from their smartphones or tablets. This modern approach enhances user engagement and allows for greater customization of the climate control experience.

Noise levels are another consideration in the design of the SAP-CMRV1926EH and SAP-CMRV1426EH-F. These units operate quietly, ensuring that they do not disrupt the tranquility of living or working spaces. Their low-noise operation is a testament to Sanyo's commitment to creating comfortable environments without compromising on performance.

In summary, the Sanyo SAP-CMRV1926EH and SAP-CMRV1426EH-F models are distinguished by their impressive cooling and heating capacities, energy-efficient inverter technology, advanced air distribution, user-friendly controls, and quiet operation. These features make them an excellent choice for anyone seeking reliable and effective climate control solutions.