5-4. How to Connect Wiring to the Terminal

WARNING

Loose wiring may cause the

terminal to overheat or result

 

 

 

in unit malfunction. A fire

 

hazard may also exist. There-

 

fore, be sure all wiring is

 

tightly connected.

When connecting each power wire to the corresponding terminal, follow the instructions “How to connect wiring to the terminal” and fasten the wire securely tight with the fixing screw of the terminal plate.

How to connect wiring to the terminal

a) For Indoor Unit

(1)Cut the wire end with a cutting pliers, then strip the insulation to expose the wire about 7 mm. See the label (Fig. 26) near the terminal plate.

(2)Using a screwdriver, loosen the terminal screw on the terminal plate.

(3)Insert the wire and tighten the terminal screw com- pletely using a screwdriver.

b) For Outdoor Unit

For solid core wiring (or F-cable)

(1)Cut the wire end with a cutting pliers, then strip the insulation to expose the solid wire about 25 mm. (Fig. 27)

(2)Using a screwdriver, remove the terminal screw(s) on the terminal plate.

(3)Using the pliers, bend the solid wire to form a loop suitable for the terminal screw.

(4)Shape the loop wire properly, place it on the termi- nal plate and fix it securely with the removed termi- nal screw using a screwdriver.

For stranded wiring

(1)Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about

10 mm and tightly twist the wire ends. (Figs. 28 and 29)

(2)Using a screwdriver, remove the terminal screw(s) on the terminal plate.

(3)Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. (Fig. 28)

(4)Place the ring connector wire, and replace and tighten the removed terminal screw using a screw- driver. (Fig. 30)

 

 

 

 

 

English

 

STRIP

7 mm (ACTUAL

 

 

 

 

 

 

SIZE)

 

 

 

SIZE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 26

mm

Solid wire

Loop

25

 

Insulation

Fig. 27

 

Stranded wire

mm

Ring

10

connector

 

Fig. 28

Twist wire ends

 

Fig. 29

 

Special

Screw

 

washer

 

 

 

Screw and

 

Ring connector

special washer

 

 

Wire

Terminal plate

Ring

 

connector

 

 

 

Wire

 

Fig. 30