Sanyo SAP-CMRV1426EH-F Major Component Specifications, Outdoor Unit SAP-CMRV1426EH

Models: SAP-CMRV1926EH SAP-CMRV1426EH-F

1 148
Download 148 pages 30.45 Kb
Page 12
Image 12
2-2. Major Component Specifications

2-2. Major Component Specifications

2-2-1. Outdoor Unit

Outdoor Unit SAP-CMRV1426EH

Control PCB

Part No.

Controls

Control Circuit Fuse

CB-CMRV1426EH

Microprocessor

250V 25A

Compressor

 

 

 

Type

 

DC Twin Rotary (Hermetic)

 

Compressor Model / Nominal Output

 

C-6RVN93H0M / 1,000W

 

Compressor Oil ... Amount

CC

FV50S ... 350

 

Coil Resistance (Ambient Temp. 20 °C)

Ohm

R - S : 0.482

 

 

 

 

 

S - T : 0.482

 

 

 

 

 

T - R : 0.482

 

Safety Device

 

 

 

 

CT (Peak current cut-off control)

 

Yes

 

 

Compressor Discharge Temp. Control

 

Yes

 

 

Operation cut-off control in abnormal ambient Temp.

Yes

 

 

Overload Relay

Model

CS-7L115

 

 

 

Operation Temp.

Open : 115 °C, Close : 95 °C

 

Run Capacitor

Micro F

-

 

 

 

 

VAC

-

 

Crankcase Heater

 

-

Fan

Type

Q'ty ... Dia.mm

Propeller 1 ... D420

Fan Motor

 

 

 

Type

 

DC Motor

 

Model ... Q'ty

 

DAJ12-55J71-CR ... 1

 

No. of Poles

 

8

 

Rough Measure RPM (Cool:Hi / Heat:Hi)

 

750 / 750

 

Nominal Output

W

50

 

Coil Resistance

Ohm

RED - WHT : 77.5

 

(Ambient Temp. 20 °C)

 

WHT - BLU : 77.5

 

 

 

 

BLU - RED : 77.5

 

Safety Device

 

 

 

 

Type

 

Internal Controller

 

 

Over- Current Protection

 

Yes

 

Run Capacitor

Micro F

-

 

 

 

VAC

-

 

 

 

 

 

Heat Exchanger Coil

 

 

 

Coil

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

2

 

Fin Pitch

mm

1.3

 

Face Area

m2

0.452

 

 

 

External Finish

 

Acrylic baked-on enamel finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

12

Page 12
Image 12
Sanyo SAP-CMRV1426EH-F, SAP-CMRV1926EH service manual Major Component Specifications, Outdoor Unit SAP-CMRV1426EH