SMC Networks EX500-GEN1 manuals
Computer Equipment > Network Card
When we buy new device such as SMC Networks EX500-GEN1 we often through away most of the documentation but the warranty.
Very often issues with SMC Networks EX500-GEN1 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Network Card SMC Networks EX500-GEN1 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Network Card on our side using links below.
SMC Networks EX500-GEN1 Instruction Manual
23 pages 1.46 Mb
Reduced wiring system Instruction ManualOPERATOR 2 Contents3 SAFETYIMPORTANT MESSAGES NOTEHandling precautions SAFETY ( continued ) 4 Product SummarySystem configuration generalGW unitManifold valve with SI unit ( SV/VQC series ) Manifold valve with SI unit ( SV/VQC series ) 6 7 5 EX500 Part NamesInstallation ( unit : mm ) 6 ()Higher-level busI/O mappingInput area mapping Status input area specifications Output area mapping 7 10 11Specification ( continued )The wirings is explained in the following order. Power supply connector Power supply for output Power supply for input and controlling GW/SI Communication connector Internal circuit Internal circuit Branch wiring : Connection from GW unit to SI unit or Input unit Lower-level busNumber of branches for input/output 4 branches ( 16 points/branch ) for input ( Note ) Max. 0.5 [A] per branch ( when SI unit and input 8 12 13Communication wiring Pin layout and connection diagram of cable with Ethernet communication connector Power supply wiring Pin layout and connection diagram of power supply connector cable for ( unit :mm ) 9 14 15Separate wiring for power supply for solenoid valves/output and for input and control of GW/SI Branch wiring 10 16 17Wiring (continued ) For GW unit Manifold valve Input unit manifold configuration For GW unit Input unit manifold configuration Type, pin layout and connection diagram of the branch cable with M12 connector ( EX500-AC - ) 18 19 11 Display/Switch Setting12 SI Unit Part Names1. SI unit for SV series valves ( EX500-S 01 ) 2. SI unit for VQC series valves ( EX500-Q ) Display/Switch Setting (continued )*1 : Remote control (SW1 all dip-switches off) *2 : DHCP Mode (SW1 all dip-switches on) *3 : Hardware Addressing Default settings 13 Mounting/WiringThe mounting and removing methods of SI unit are as shown below. ( EX500-Q 02 )SI Unit for VQC Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) Note 2M3 30 : 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly M3 10 : 2 pcs. ( Hexagon socket head cap screw ( with spring washer )) 1. SI unit for SV series valves ( EX500-S 01 ) 2. SI unit for VQC series valves ( EX500-Q 01 ) 14 SI unit for SV series valves ( EX500-S 01 )SI unit for VQC series valves ( EX500-Q ) 1. SI unit for SV series valve ( EX500-S 01 ) 2. SI unit for VQC series valve ( EX500-Q ) 3. Applicable valve series When only input blocks for M8 connector are connected When only input blocks of 8-point-integrated type are connected 15 Input Unit Manifold Part NamesSpecifications for Input unit Dimensions ( unit : mm ) (continued ) 16 Installation18 EX9 Series General Purpose Output Block Part Names1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2 Output wiring EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 output connectors 19 Mounting Dimensions when general purpose output block is connectedPin alignment and connection drawing of the Output Cable 20 Power supply wiringEX9-PE1 power supply connector No.0 EX9-PE1 power input connector No.1Pin alignment and connection drawing of the Power Supply Cable 21 1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP21. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 22 OptionEtherNet/IP compatible communication 23 Troubleshooting
Also you can find more SMC Networks manuals or manuals for other Computer Equipment.