Specification ( continued )

Lower-level bus

Number of branches for

4 branches ( 16 points/branch ) for input

input/output

4 branches ( 16 points/branch ) for output

 

 

Communication method

Protocol : Dedicated for SMC

 

Speed : 750kbps

 

 

 

Branch current for input

Max. 0.5 [A] per branch ( when SI unit and input

( Note )

devices are connected )

 

 

 

 

Branch current for output

Max. 0.65 [A] per branch

 

 

( when SI unit EX500-S

01 is connected )

 

Max. 0.75 [A] per branch

 

 

( when SI unit EX500-Q

is connected )

 

 

Branch cable length

5m or less between devices

 

( total extended length : 10m or less )

 

 

 

Note : Total value of maximum current consumption and maximum load current of input devices to connect.

Wiring

Internal circuit

Communication

+Tx

1

+Rx

2

connector

- Tx

3

 

- Rx

4

 

Power supply

 

0V

 

 

 

 

Power

for output

 

1

 

 

+24V

2

 

 

Power supply

 

 

supply

 

0V

3

 

 

connector

for input and

+24V

4

 

 

 

controlling GW/SI

 

PE

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC-DC

converter

Internal circuit

1RD+

2RD -

3TD+

4TD -

5+24V

60V

7+24V

80V

1RD+

2RD -

3TD+

4TD -

5+24V

60V

7+24V

80V

COM A

COM D

The wirings is explained in the following order.

Communication wiring : Connection with EtherNet/IP

Power supply wiring : Connections of power supplies for solenoid valves/output devices, and for input devices and controlling GW/SI

Branch wiring : Connection from GW unit to SI unit or Input unit

10

11

Page 7
Image 7
SMC Networks EX500-GEN1 instruction manual Wiring, Specification, Lower-level bus, Internal circuit