Wiring
Branch wiring
For wiring method, refer to subsection "Wiring" ( page 15 ) of section "EX500" in this manual. To input devices such as sensor, the power is supplied through the branch wiring ( branch cable with M12 connector ). Therefore, there is no need to supply the power to them individually.
Sensor wiring | Sensor connector "1" |
Connect sensors to the sensor | Sensor connector "0" |
connectors of input block. |
|
Pin layout of sensor connector
M8 connector ( |
| M12 connector ( |
| ||
Power supply |
|
| Power supply |
|
|
( 24VDC ) | 1 |
| ( 24VDC ) | 1 | 2 |
Power supply ( 0V ) |
|
| ( Input ) ( Note ) |
|
|
Input | 4 | 3 | Power supply ( 0V ) | 4 | 3 |
| Input | ||||
|
|
|
|
|
Note : Internal wiring of M12 input block and key position for mounting sensor connector
Correspondence between input number and input block
Input block up to 8 can be connected ( 16 points ).
Input numbers are 0 to 15 from Input unit side.
Input unit 0 | 2 | 4 | 6 | 8 | 10 | 12 |
| 14 |
0 | 0 | 0 | 0 | 0 |
| 0 | 0 | 0 |
1 | 1 | 1 | 1 | 1 |
| 1 | 1 | 1 |
1 | 3 | 5 | 7 | 9 | 11 | 13 |
| 15 |
Display
Power LED
Indicator LED
No. 2 pins of M12 input block connectors are wired to each other’s sensor signal input pins ( No. 4 pins ) internally.
This wiring enables direct input of signals from two points combined into one cable through concentric connector etc.
When connecting sensors, confirm the specification of output signal carefully. Otherwise malfunction can result.
The key position for mounting sensor connector is as shown to the right. Consider this key position when selecting sensor.
Input "0" ( n ) side | Input "1" ( n+1 ) side | ||
4 |
|
| 2 |
0 |
| key | 1 |
|
|
| |
3 | 1 | 1 | 3 |
2 | key |
| 4 |
|
| ||
Input "1" ( n+1 ) |
|
|
|
Input "0" ( n ) |
|
|
|
M12 Block
Display | Description |
Power LED | Lights on : Power for input and controlling GW is supplied. |
| Blinks : Under short circuit protection ( abnormal status ). |
| As the short circuit protective function is operating, the power |
| is not supplied. |
| To cancel blinking, turn off and return the power to GW unit. |
| Lights off : Power for input and controlling GW is not supplied. |
NOTE
Mount a waterproof cap on each unused connector of Input unit. The proper use of waterproof cap can achieve IP65 Enclosure. The waterproof caps are delivered together with each input block as accessories.
( Tightening torque : 0.05Nm for M8 and 0.1Nm for M12 )
Indicator | Lights on : Sensor signal input ON ( logical "1" ) |
LED | Lights off : Sensor signal input OFF ( logical "0" ) |
30 | 31 |