Input Unit Manifold Part Names

The Input unit manifold consists of Input unit, input block (s), end block and DIN rail. The input block up to 8 can be connected ( 16 points ).

Any combination of input blocks ( for M8 connector, M12 connector and 8-point- integrated type ) is acceptable.

Note Do not mix sensor input specifications ( PNP and NPN ).

Figure shows the configuration when only input blocks for M8 connector are connected.

No.

Part name

Application

1

Input unit

Unit to communicate with GW unit or SI unit.

 

 

 

2

Communication

To be connected with branch cables from GW unit or

 

connector

SI unit ( branch cable with M12 connector ). ( Note1 )

 

 

 

3

Power LED

Indicates the power supply status. ( Note2 )

 

 

 

4

Input block

Unit for sensor signal input.

 

 

 

5

Sensor connector

Connects with sensor. ( Note1 )

 

 

 

6

Indicator LED

Indicates sensor signal status. ( Note2 )

 

 

 

7

Marker

To be used for writing input No. etc.

 

 

 

8

End block

Composes the end of Input unit manifold.

 

 

 

9

DIN rail

To be mounted with Input unit manifold.

 

 

 

Note1 : For wiring method, refer to subsection "Wiring" ( page 30 ) of section "Input Unit Manifold" in this manual.

Note2 : For display, refer to "Display" ( page 31 ) in section "Input Unit Manifold" in this manual.

Dimensions ( unit : mm )

When only input blocks for M8 connector are connected

 

DIN Rail

35

49

L3

(L4)

L2 ( Rail mounting pitch: 12.5 )

5

L1

 

44.2

(7.5)

32.2

39.7

 

Stations

1

2

3

4

5

6

7

8

L1

[mm] : Rail length

98

110.5

123

135.5

148

160.5

173

185.5

 

 

 

 

 

 

 

 

 

 

L2

[mm] : Mounting pitch

87.5

100

112.5

125

137.5

150

162.5

175

 

 

 

 

 

 

 

 

 

 

L3

[mm] : Manifold length

74

86

98

110

122

134

146

158

 

 

 

 

 

 

 

 

 

 

L4

[mm]

12

12

12.5

12.5

13

13

13.5

13.5

 

 

 

 

 

 

 

 

 

 

When only input blocks of 8-point-integrated type are connected

 

Stations

1

2

L1

[mm] : Rail length

135.5

185.5

 

 

 

 

L2

[mm] : Mounting pitch

125

175

 

 

 

 

L3

[mm] : Manifold length

110

158

 

 

 

 

L4

[mm]

12.5

13.5

 

 

 

 

26

27