SMC Networks EX500-GEN1 instruction manual EX9-OET1/EX9-OET2 EX9-PE1, Part name Application

Models: EX500-GEN1

1 23
Download 23 pages 14.41 Kb
Page 18
Image 18

EX9 Series General Purpose Output Block Part Names

The EX9 series general purpose output block is the unit to operate solenoid valve, relay, etc. in combination with VQC and SV ( tie-rod ) series valve and applicable SI unit. There are two types ---- one type is for low wattage load ( EX9-OET1 or EX9-OET2 ) that

outputs signals by receiving power supply from SI unit, and the other type is for high wattage load ( EX9-OEP1 or EX9-OEP2 ) that outputs signals by receiving power supply from outside. The type for high wattage load is used in combination with the power block ( EX9-PE1 ) connected with external power supply. As the low-wattage-load type is powered from SI unit, the wattage of load is limited to 1.0W ( Note ). For a load up to 12W, use the power block and the high-wattage-load type.

Note : When connected with EX500 series.

1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2

VQC series

 

 

SI unit for

 

 

VQC series

 

 

( EX500-Q 02 )

No.

Part name

Application

2. EX9-PE1

VQC series

 

 

SI unit for

 

 

general purpose

 

 

output block

 

 

( EX500-Q 02 )

No.

Part name

Application

1

Power supply connector

Unused

2

Power input connector

Supplies power for output devices. ( Note1 )

3

Power LED

Indicates the power supply status. ( Note2 )

Note1 : For wiring method, refer to subsection "Wiring" ( page 35 ) of section "EX9 Series General Purpose Output Block" in this manual.

Note2 : For display, refer to subsection "Display" ( page 39 ) in section "EX9 Series General Purpose Output Block" in this manual.

Dimensions ( unit : mm )

1. EX9-OET1/EX9-OET2/

2. EX9-PE1

EX9-OEP1/EX9-OEP2

 

1

Output connector

Connects with output device. ( Note1 )

 

 

 

2

Indicator LED

Indicates the output status. ( Note2 )

Note1 : For wiring method, refer to subsection "Wiring" ( page 35 ) of section "EX9 Series General Purpose Output Block" in this manual.

Note2 : For display, refer to subsection "Display" ( page 39 ) of section "EX9 Series General Purpose Output Block" in this manual.

72.6

21.2

21.2

 

59.8

 

43.2

 

22.2

21

26.7

80.3

PWR

59.8

43.2 22.2

21

26.7

32

33

Page 18
Image 18
SMC Networks EX500-GEN1 instruction manual EX9-OET1/EX9-OET2 EX9-PE1, Part name Application