SMC Networks EX500-GEN1 Display, SI unit for SV series valve EX500-S, Applicable valve series

Models: EX500-GEN1

1 23
Download 23 pages 14.41 Kb
Page 14
Image 14

Specification

1. SI unit for SV series valve ( EX500-S

01 )

 

Item

Specification

Connected block

Solenoid valve ( single, double )

 

Relay output module ( 1-point output, 2- point output )

 

 

 

 

Connected block

Double solenoid valve

 

Max. 8 stations

station

Relay output module ( 2-point output )

 

 

 

 

 

 

Single solenoid valve

 

Max. 16 stations

 

Relay output module ( 1-point output )

 

 

 

 

 

Supply voltage for block

24VDC

 

 

 

 

 

 

Supply current for block

0.65A Max.

 

 

 

 

Current consumption

100mA or less ( at rated voltage )

 

 

 

 

2. SI unit for VQC series valve ( EX500-Q )

Item

Specification

 

Connected block

Solenoid valve ( single, double )

 

 

General purpose output block ( EX500-Q

02 only )

 

 

 

Connected block

Double solenoid valve

Max. 8 stations

station

 

 

Single solenoid valve

Max. 16 stations

 

 

 

 

 

General purpose output block

Max. 8 stations

 

( EX500-Q 02 only )

 

 

 

 

 

Supply voltage for block

24VDC

 

 

 

 

Supply current for block

0.75A Max.

 

 

 

 

Current consumption

100mA or less ( at rated voltage )

 

 

 

 

3. Applicable valve series

Series

Manifold

Inner diameter of applicable cylinder tube ( mm )

Cassette Tie-rod

40

50

63

80 100 125

 

SV1000

 

 

 

 

 

SV2000

 

 

 

 

 

SV3000

-

 

 

 

 

SV4000

-

 

 

 

 

VQC1000

-

 

 

 

 

VQC2000

-

 

 

 

 

VQC4000

-

 

 

 

 

For detailed specifications of solenoid valve and manifold, refer to the catalogs, instruction manuals, technical data, etc. of each valve series.

Display

SI unit for SV series valves ( EX500-S 01 )

Power LED

Communication LED

SI unit for VQC series valves ( EX500-Q )

Communication LED

Power LED

Common to EX500-S

01/EX500-Q

 

 

Display

Description

Power LED

Lights on : Power to solenoid valves/output is supplied at the

 

specified voltage.

 

Lights off : Power to solenoid valves/output is not supplied at

 

the specified voltage. ( Voltage dropped to lower

 

than 20V. )

 

 

Communication

Lights on : Receiving data from GW

LED

Lights off : No received data

 

 

24

25

Page 14
Image 14
SMC Networks EX500-GEN1 Display, SI unit for SV series valve EX500-S, SI unit for VQC series valve EX500-Q, Led