Chapter 2 Provisioning

Step by Step Installation and Initial Configuration

System Startup

This section describes how to start the Cisco CNS Security and Cisco CNS Integration Bus processes and then perform a Cisco PTC Cold Start. A Cisco PTC Cold Start does the following:

creates and initializes the Cisco PTC database

loads the data types and meta information

starts the orbixd daemon, the Event Distributor, and the ACT Server

starts the Cisco PTC Provisioning, Topology, Northbound API, Synchronization Manager, and Auto discovery Servers

uploads the running configurations of the devices found in the Cisco PTC Network Information Seed File (NISF), parses them, and then populates the Cisco PTC database. The NCSF provides to Cisco PTC, a list of the network elements and their properties that are to be managed by Cisco PTC.

starts the Cisco VRC application if it is installed and the vnm --coldstart--INTEGRATEDcommand is executed.

Step 1 Log into the Cisco PTC host, as user vnm, with an Xwindow terminal and start the Cisco CNS Security Server process:

ptc-tme# su - vnm

Sun Microsystems Inc. SunOS 5.8 Generic Patch October 2001

Path and environment for DC Directory set up

ptc-tme% dcdstart

Starting DC Directory Server...

DC Directory Server initializing ...

DC Directory Server initialized

Note Upon starting the Cisco CNS Security Server process, error messages containing “seminfo_semmin is not defined in the semsys” and “seminfo_semune is not defined in the semsys” may be output. These error messages are not serious and can be ignored.

Step 2 Verify the Cisco CNS Security process is running:

ptc-tme%ps -ef grep dcx500

root 2165

1 2 15:52:53 pts/3

0:09

/opt/cisco/vnm/common/dcdsrvr/bin/dcx500

Step 3 If it isn't running (the dcx500 daemon was not found), go back and restart the DCD server.

Step 4 Start the Cisco CNS Integration Bus process:

ptc-tme%startCnsBus

Starting CNS INTEGRATION BUS

 

 

TIB/Rendezvous daemon

 

 

Copyright 1994-2000 by TIBCO Software Inc.

 

 

All rights reserved.

 

 

Cisco Internet OSS for VoIP: Infrastructure Manager Implementation Guide

 

 

 

 

 

 