Changing the Parameter Settings |
question mark (?) after the particular value. For example, to read the status of S register 63, you would type
AT S63?
and then press [Enter] or [Return].
After completing its tasks, the 3C882 ISDN modem sends a message to the screen followed by a result code. Refer to Appendix B for a complete list of result codes.
5To change another parameter setting, repeat steps 1 through 4. Otherwise, go on to Chapter 7, “Placing and Receiving Calls.”
Table
Parameter | Default Value | To Change the Default |
|
|
|
QuickSelect | Enabled (S71=0) | Send the command ATS71=1 to use |
|
| PPP exclusively or ATS71=2 to use V.120 exclusively. |
DBA | Enabled for both | Send the command ATS70=0 to disable DBA. |
| incoming and |
|
| outgoing calls |
|
| (S70=3) |
|
Auto Answer | Disabled (S0=0) | Send the command ATS0=(number of rings before |
|
| the ISDN modem answers the call) to enable Auto |
|
| Answer. |
Compression | Enabled (%C2) | Send the command AT%C0 to disable compression. |
Autobaud | Enabled ($B0) | Send the command AT$B (rate) to set a specific |
|
| baud rate. Acceptable values are 1200, 2400, 4800, |
|
| 9600, 19200, 38400, 57600, 115200, and 230400.* |
|
| Send the command AT$B0 to return to Autobaud. |
|
| Autobaud does not exceed 115200. For 230400 you |
|
| must send the command AT $B230400 to the ISDN |
|
| modem. |
|
|
|
* To access the Configuration dialog box, the baud rate must be set to Autobaud.