2-10CHAPTER 2: DUAL T1/PRI CONFIGURATION

Configuring

Configure inbound call routing by selecting option 4 from the UI console’s

Inbound Call

main menu.

Routing

 

 

 

 

 

Copyright 3Com Corporation, 1998

 

 

Dual T1/PRI Application Card Revision 3.1.4 (Card Id: 27)

 

 

Boot Code Linked Date : Mon Dec 04 17:41:48 1995

 

 

Operation Code Linked Date: Tue Feb 23 16:41:51 1999

Main Menu

1Command

2Status

3Card Configuration

4Inbound Call Routing Configuration

5Span Line 1 Configuration

6Span Line 2 Configuration

7SW Fault Manager Event Logging

8Logout

Enter menu selection and press Return.

Menu Selection (1-8):

Pressing option 4 at the main menu prompt produces this screen:

Inbound Call Routing Configuration

 

 

Current

1

Default ISDN-GW Slot: 16

 

2

Allow Analog Modem Calls:

Disabled

3

Inbound Phone Number Routing Configuration

4

Inbound Phone Number Routing Configuration Status (Entries 1-24)

5

Inbound Phone Number Routing Configuration Status (Entries24-48)

6

Reserved Pool to Inbound Phone Number Assignment

7

Modem/ I-Modem to Reserved Pool Assignment

8

ISDN-GWC to Reserved Pool Assignment

9 Allow ISDN-GWC

Enter menu selection and press Return or press Esc to exit.

Menu Option 1 Selecting a Gateway to process digital calls

Digital calls handled by the T1/PRI are passed along to an ISDN-GW (ISDN-Gateway (NETServer PRI)) in the Total Control chassis to be processed. The T1/PRI must be configured as to the location (chassis slot number) of the ISDN-GW it is to communicate with.

The ISDN-GW is located in slots 1–16 of the Total Control chassis.

If no Gateway is installed, enter N at the prompt.

Menu Option 2 Allowing modem analog calls

Enabling this option allows the chassis to accept incoming analog modem calls and route them appropriately.

Page 22
Image 22
3Com T1/PRI manual Configuring, Inbound Call, Routing, Menu Option 1 Selecting a Gateway to process digital calls