3Com T1/PRI manual Correcting Alarm/Error Conditions, Alarm/Error Level Trouble Clearing

Models: T1/PRI

1 52
Download 52 pages 9.78 Kb
Page 46
Image 46

Correcting

Alarm/Error

Conditions

Using the LEDs A-3

Alarm/Error

Level

Trouble Clearing

 

 

 

 

Remote Frame Alarm

Yellow

Verify that the NAC is configured

(RFA)

 

 

properly according to the services

 

 

 

provisioned by the Telco. Contact the

 

 

 

Telco if necessary.

 

 

Check the cables—do not use a flat

 

 

 

cable.

 

 

Check break-out boxes.

 

 

Examine boot-up test results.

 

 

Examine error counters.

 

 

 

 

Loss of Signal (LOS)

N/A

Verify that the span is plugged into

 

 

 

the NIC properly.

 

 

If the cabling is correct, there is most

 

 

 

likely a problem at the Telco. Contact

 

 

 

the Telco for service.

 

 

Check the cables—do not use a flat

 

 

 

cable.

 

 

Check break-out boxes.

 

 

Examine boot-up test results.

 

 

Examine error counters.

 

 

 

 

Out-of-Frame (OOF)

Red

Verify that the NAC is configured

 

 

 

properly according to the services

 

 

 

provisioned by the Telco.

 

 

If your configuration is correct, there

 

 

 

may be a problem with the Telco’s

 

 

 

equipment. Contact the Telco for

 

 

 

service. Check the cables—do not use

 

 

 

a flat cable.

 

 

Check break-out boxes.

 

 

Examine boot-up test results.

 

 

Examine error counters.

 

 

Check framing mode configuration.

 

 

 

 

Unframed All Ones

Blue

Indicates a red alarm at the Telco.

(AIS)

 

 

Contact the Telco for service.

 

 

 

 

RFA and Continuous

N/A

Verify that the NAC is configured

CRC (CCRC) Errors

 

 

properly according to the services

 

 

 

provisioned by the Telco.