Correcting

Alarm/Error

Conditions

Using the LEDs A-3

Alarm/Error

Level

Trouble Clearing

 

 

 

 

Remote Frame Alarm

Yellow

■

Verify that the NAC is configured

(RFA)

 

 

properly according to the services

 

 

 

provisioned by the Telco. Contact the

 

 

 

Telco if necessary.

 

 

■ Check the cables—do not use a flat

 

 

 

cable.

 

 

■ Check break-out boxes.

 

 

■ Examine boot-up test results.

 

 

■

Examine error counters.

 

 

 

 

Loss of Signal (LOS)

N/A

■

Verify that the span is plugged into

 

 

 

the NIC properly.

 

 

■ If the cabling is correct, there is most

 

 

 

likely a problem at the Telco. Contact

 

 

 

the Telco for service.

 

 

■ Check the cables—do not use a flat

 

 

 

cable.

 

 

■ Check break-out boxes.

 

 

■ Examine boot-up test results.

 

 

■

Examine error counters.

 

 

 

 

Out-of-Frame (OOF)

Red

■

Verify that the NAC is configured

 

 

 

properly according to the services

 

 

 

provisioned by the Telco.

 

 

■ If your configuration is correct, there

 

 

 

may be a problem with the Telco’s

 

 

 

equipment. Contact the Telco for

 

 

 

service. Check the cables—do not use

 

 

 

a flat cable.

 

 

■ Check break-out boxes.

 

 

■ Examine boot-up test results.

 

 

■

Examine error counters.

 

 

■ Check framing mode configuration.

 

 

 

 

Unframed All Ones

Blue

■

Indicates a red alarm at the Telco.

(AIS)

 

 

Contact the Telco for service.

 

 

 

 

RFA and Continuous

N/A

■

Verify that the NAC is configured

CRC (CCRC) Errors

 

 

properly according to the services

 

 

 

provisioned by the Telco.

(continued)

Page 46