Chapter5. The Serial Console

Load preliminary configuration

Theconfiguration file selected here will be uploaded as a preliminary configuration. The permanent configuration
willnot be affected.
Toload the configuration, select this alternative and then start the transfer in your terminal program.

Load both configurations and apply

Theconfiguration file selected here will be uploaded as both the preliminary and the permanent configuration.
Whenthe upload is finished, the configuration will be applied.
Toload the configuration, select this alternative and then start the transfer in your terminal program.

Save preliminary configuration

Savethe preliminary configuration to a file. If your terminal program starts the transfer automatically, the file will
benamed config.cfg.

Save permanent configuration

Savethe permanent configuration to a file. If your terminal program starts the transfer automatically, the file will be
namedconfig.cfg.

Main menu

Selectthis alternative to return to the main menu.
Become a failover team member
Here,you make the Telecommuting Module the second member of a failover team. All current configuration will be
removed.The Telecommuting Module will receive its new configuration from the first member of the team.
Dedicatednetwork interface [eth0]:
Selectthe network interface which will be directly connected to the other Telecommuting Module in the team. This
interfacewill be used to synchronize the configurations and can’t be used for anything else. The interfaces use their
physicalnames: if you want to use Network Interface 1, enter "eth0", and if you want to use Network Interface 2,
enter"eth1".
IPnetwork address for eth0 [10.120.121.64]:
Enterthe network address for this interface. The network address must be the same as the one entered for the first
memberof the failover team. If you used the default values for that Telecommuting Module you can do the same
here.
IPnetmask for eth0 [255.255.255.252]:
Enterthe netmask for the network. The netmask must be big enough to comprise IP addresses for two computers, a
networkaddress and a broadcast address, i.e. at least four addresses. The default netmask (255.255.255.252) should
suffice.There is no use in assigning a larger network, since the Telecommuting Modules should be connected via a
crossoverTP cable.
Currentconfiguration:
Dedicatedinterface: eth0
Networkaddress: 10.120.121.64
Networkmask: 255.255.255.252
Isthis configuration correct (yes/no/abort)?
Whenall settings are made they are shown.