−− There are two options for measuring depth. Live depth is a continuous measurement.

1-Shot Depth is an averaging of the depth reading over a short period of time. When in 1-Shot mode, the unit will average the depth reading for three seconds, and then display the result on the display. Press Depth [SK] to alternate between the two modes.

−− Five depth readings can be saved with the time, date and relative current measurements.

3.Pressing Save [SK] will place each entry in sequential order in memory (M1 - M5) until five readings have been stored. The unit will overwrite saved entries in excess of five, beginning with M1.

4.Press Clear All [SK] to delete all stored depth information.

−− The operator may select the memory location to store the depth readings by pressing Mem Select [SK]. When the preferred location appears on the display, press Save [SK]. The display and memory location will populate with the current information.

−− Each memory location can be reviewed by pressing Mem Select [SK].

5.Press Locate/OK [5] to return to Locate Mode.

9.Locating Frequencies

A. Active Frequencies

Active frequencies are trace signals supplied by a 3MDynatelTransmitter 2200 Series (577 Hz, 8 kHz, 33 kHz, or 200 kHz).

1.Select the same frequency that the transmitter is generating.

2.Press Locate/OK [5]

3.Press Cable/Pipe [SK]

4.Press Freq [SK]

5.Press Active [SK Toggle] until the desired frequency is displayed in the soft key command [9] (“Active” 577, 8K, 33K or 200K)

6.Press Locate/OK [5] to return to Locate mode.