25. Transmitter Specifications

Item

Specification

Trace Mode

577 Hz

 

8 kHz

 

33 kHz

 

200 kHz

Fault Mode

10/20 Hz - Fault signal

(2273M models only)

577 Hz / 33 kHz -Trace signal

 

Note: The fault locating limit is 2.0Malthough the transmitter's ohmmeter

 

mode can display a fault resistance up to 10M.

Tone Mode

577 Hz and 200 kHz pulsing at 8 Hz

Induction Mode

8 kHz (only available on 12 Watt Transmitter)

 

33 kHz

 

200 kHz

Output Power

3 Watt Transmitter Model

(in Direct Connect mode)

Normal setting: 0.5 W

 

High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz

 

5 Watt Transmitter Model

 

Normal setting: 0.5 W

 

High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz

 

Maximum setting: 5 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz

 

(with external DC power source)

 

12 Watt Transmitter Model

 

Normal setting: 0.5 W

 

High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz

 

Maximum setting: 12 W @ 577 Hz, 8 kHz; 10 W @ 33 kHz; 1 W @ 200 kHz

 

(with external DC power source)

Output Voltage (Maximum)

70 Vrms

Output Protection

240 Vrms

Weight w/batteries

w/ alkaline batteries only: 5.2 lbs (2.4 kg)

 

w/ rechargeable battery (2200RB) and alkaline batteries (5W and 12W

 

transmitters only): 9.2 lbs (4.2 kg)

Battery Qty. and size

For Normal and High Output Power: 6 "C" size, Alkaline (LR14)

 

For Maximum Output Power: Rechargeable Battery (2200RB), 12V-6AH,

 

Sealed Maintenance-Free Lead (Pb)-Acid Battery

 

(See safety information below.)

Battery Life

Normal Output Power level: 50 hours typical

 

High Output Power level: 10 hours typical

 

Typical transmitter specified battery life (listed above) is increased by 40%

 

when using the 2200RB Rechargeable Battery (12 volt). Using the 2200RB

 

bypasses the alkaline batteries.

 

Maximum Output Power level: 4 hours typical (Maximum Output Power level

 

achieved using 2200RB Rechargeable Battery.)

External DC Power

9–18 V DC

Rechargeable Battery fuse

5 Amp / 32 Volt

 

Littelfuse MINI® Blade # 0297005

Cigarette Lighter Adapter

4 Amp / Fast Blow 250V

Cable fuse

 

78-8130-6150-0 Rev G

63