TROUBLESHOOTING

CER-TEMP 80 RECOVERY SYSTEM CHECKOUT PROCEDURE

Use this checkout for Cer-Temp 80 Recovery Systems. (For hot water supply application only)

Checkout Sequence

System Operation

Cause

Remedy

Contact

Incorrect

 

 

 

 

 

Pump and burner remain

Tank temperature control

Replace.

 

 

(thermostat) defective.

 

 

Circulating pump and

on.

System wiring is

Correct wiring.

 

 

incorrect.

Set tank temperature

burner shut off.

 

 

control (thermostat) 20°F

 

Circulating pump on.

Pump wired for

Correct wiring.

(10°C) below tank water

With thermal balancer,

continuous operation.

 

 

temperature.

pump off delay of

 

 

 

 

Gas valve stuck or

Correct or replace

 

approximately 2 minutes.

 

 

Burner on.

defective.

valve.

 

 

 

 

System wiring is

Correct wiring.

 

 

 

 

 

 

incorrect.

 

 

 

 

 

 

 

High limit control set too

Replace. (If problem

 

 

 

low.

proven to be at this

 

 

 

High limit control

control by applying

 

 

 

differential too wide.

jumper to terminals.)

 

 

Circulating pump on.

System wiring is

Correct wiring.

 

 

incorrect.

 

 

 

 

Set tank temperature

 

 

Coil protector switch has

Remove control cover,

control (thermostat) 20°F

Circulating pump and

 

activated.

depress reset button.

(10°C) above tank water

burner on.

 

Gas valve or wiring

Check wiring. Repair or

temperature.

 

 

defective.

replace valve.

 

 

 

Power off or system

Check power supply

 

 

Circulating pump and

wiring is incorrect.

and wiring.

 

 

burner off.

Tank temperature control

Replace.

 

 

 

 

 

 

(thermostat) defective.

 

 

 

Burner on.

System wiring is

Correct wiring.

 

 

incorrect.

 

 

 

 

 

 

 

High limit control

 

Boiler outlet temperature

Circulating pump on.

Circulating pump and

defective, or set too high

Replace.

exceeds 210°F (100°C).

 

burner on.

(max. should be set at

 

 

 

 

200°F).

 

Set tank temperature

 

 

 

 

control (thermostat)

System maintains desired

 

 

 

for desired water

water temperature.

 

 

 

temperature.

 

 

 

 