Note: Make sure all remnants of concrete are removed from the PMF prior to mounting the cabinet. It is not necessary to use shims to level or align the cabinet as long as the top surface of the PMF is clean and free of any installation debris.
2.If a ground spacer will not be installed, proceed to step 7. If a ground spacer (accessory) will be installed, align the ends of the left ground spacer section with the ends of the right ground spacer section and then press the two sections together.
3.Place the assembled ground spacer in position for mounting on the PMF as shown in Figure 11.
CABINET (FRONT)
HEX BOLTS, FLAT
WASHERS, AND
NUTS (4 PLACES)
| GROUND | |
CAPSCREWS, LOCK | SPACER | |
(ACCESSORY) | ||
WASHERS, AND FLAT | ||
| ||
WASHERS (4 PLACES) |
| |
CONCRETE |
| |
PAD |
| |
|
PAD MOUNTING
FRAME (PMF)
CABLE
CONDUIT
Figure 11. Mounting the
4.Align the mounting holes in the ground spacer with the mounting holes in the PMF.
5.Secure the ground spacer to the PMF using the four capscrews, four lock washers, and four flat washers provided with the cabinet. Tighten all capscrews securely.
Page 20