INTRODUCTION

AD-410 MACHINE OPERATIONAL SUMMARY

The model AD-410 incorporates one (1) “EMERGENCY STOP (E-Stop) BUTTON” located centrally on the Right Front Control Door. This "RED" MUSHROOM PUSH-BUTTON is “PUSH TO STOP” the machine and “TURN TO RELEASE” or “PULL TO RELEASE” type control device. This button must be in the released mode to power the machine. The PHASE 5 MICROPROCESSOR CONTROLLER (Computer) display will light when the “EMERGENCY STOP (E-Stop) BUTTON” is in the released mode. To turn “ON” the control voltage, press the green “ONpush-button located on the Right Front Control Door.

The dryer has two (2) electronic controllers:

PHASE 5 MICROPROCESSOR CONTROLLER (Computer) - for drying material

MICRO-1 PLC (Programmable Logic Controller) - for loading, unloading auto doors, and burner status monitoring

The Phase 5 Microprocessor Controller (computer) only response to keypad (touchpad) commands when the tumbler section is level with the loading doors and lint drawer/basket door closed. Likewise, the Micro-1 PLC (Programmable Logic Controller) responses to load or unload selections when the dryer is not drying material.

AD-410 OPERATOR CONTROLS/INDICATORS

The Right Front Control Door incorporates the following operator controls/indicators: EMERGENCY STOP (E-Stop) BUTTON (Push To Stop/Turn or Pull To Release) JOG (Forward/Reverse Push-Buttons)

UNLOAD/DRY / LOAD (Selector Switch)

TILT FUNCTION (Off - On Selector Switch)

HEATER FAULT (Indicator/Reset Push-Button)

CONTROL POWER (Indicator/Control Power On Push-Button)

CONTROL POWER (Off Push-Button)

5

Page 9
Image 9
ADC service manual AD-410 Machine Operational Summary, AD-410 Operator CONTROLS/INDICATORS