3.Troubleshooting and System Detailed Diagnosis
When the dryer calls for heat, 24 VAC from the step down transformer is applied to the "TH" and "GND" terminals of the DSI (Direct Spark Ignition) module. The DSI module L.E.D. (light emitting diode) indicator will light "red" (for up to approximately
ARE NO RETRIES.
NOTE: If a fault is sensed, the "HEATER FAULT" indicator and the "End of Cycle" indicator will begin to flash at a rate of one (1) flash per second. Both indicators will flash until the "HEATER FAULT" reset
To reset the dryer when a "HEATER FAULT" occurs, press the ("amber") "HEATER FAULT" reset
If a flame has been established and confirmed and then lost, the DSI (Direct Spark Ignition) module L.E.D. (light emitting diode) indicator will continue to light "green" and immediately a spark will be evident (on) for approximately
RETRIES.
NOTE: If a fault is sensed, the "HEATER FAULT" indicator and the "End of Cycle" indicator will begin to flash at a rate of one (1) flash per second. Both indicators will flash until the "HEATER FAULT" reset
To reset the dryer when a "HEATER FAULT" occurs, press the ("amber") "HEATER FAULT" reset