3.Sprinkler System Component Replacement
a. Resistive Temperature Device (RTD) Replacement
1)Turn the water supply to the dryer off.
2)Discontinue electrical service to the dryer.
3)Remove the 1/4" compression fitting.
4)Remove the two (2) screws from the junction box cover.
5)Remove the wires of the RTD (Resistive Temperature Device) from the terminal strip.
NOTE: Identify the wires removed for proper reinstallation.
6)Loosen the cord grip cap.
7)Remove Resistive Temperature Device (RTD).
8)To install new RTD (Resistive Temperature Device), reverse above procedure..