Addlogix iDP-3410 user manual ESC n, ESC ⁄ n data CR or LF

Models: iDP-3410

1 152
Download 152 pages 21.01 Kb
Page 112
Image 112
Manual background

iDP-3410 User’s Manual

ESC "{ " n

[Function]

Specifying/Canceling the inverted character print

[Code]

<1B>H <7B>H n

 

 

[Range]

0 n 255

 

 

[Outline]

This command selects/deselects inverted print. n is valid only for the least significant bit.

 

 

 

 

 

 

 

 

n

 

Type

 

0Deselects the inverted characters.

1Selects the inverted characters.

[Caution]

This command is valid only if entered at the head of the line.

 

 

[Default]

n = 0

<Example>

When Inverted Print Is

When Inverted Print Is

 

 

 

 

 

 

Deselected

Selected

 

 

Print

 

 

 

 

 

 

 

 

ESC "" n "data" CR or LF

Direction

 

 

 

 

 

 

 

 

 

 

 

 

 

[Function]

Defining the message

 

 

 

 

[Code]

<1B>H <2F>H n “data” CR or LF

 

 

 

[Range]

1 n 10

 

 

 

 

[Outline]

This command defines up to a 50-byte message in one line.

If the value of n is specified

 

beyond the range, the data following n will be treated as the print data.

 

Once the message is defined, it remains valid until it is redefined. The data should end with

CR (0DH) or LF (0AH). If the data exceeds 50 bytes, the subsequent data will be treated as the print data.

Once the message is defined, it remains valid until it is redefined or the download deletion command (ESC DC2 n1 n2) is executed.

Page 112
Image 112
Addlogix iDP-3410 user manual ESC n, ESC ⁄ n data CR or LF