Addlogix iDP-3410 user manual Input and Output Signals

Models: iDP-3410

1 152
Download 152 pages 21.01 Kb
Page 34
Image 34
9.3Input and Output Signals

iDP-3410 User’s Manual

9.3Input and Output Signals

9.3.1Input and Output Signals

(1)Input signals to the printer

 

DATA

: An 8-bit parallel signal. (Positive logic)

 

 

 

 

 

 

 

: A strobe signal to read the 8-bit data. (Negative logic)

 

STB

 

 

 

: A signal to reset the printer from the outside.(Negative logic)

 

RESET

(2) Output signals from the printer

 

 

 

 

 

 

: An 8-bit data request signal. A pulse signal output at the end of the BUSY signal.

 

ACK

 

 

 

 

 

 

 

(Negative logic)

 

BUSY

: A signal to indicate the BUSY status of the printer. Input new data when at "LOW".

 

 

 

 

 

 

 

(Positive logic)

 

 

 

 

 

: A signal turned to "LOW" when the printer has an alarm. At this time, all the control

 

FAULT

 

 

 

 

 

 

 

circuits in the printer stop. (Negative logic)

 

SELECT

: A signal to show whether the printer is selected(on-line) or deselected.(Positive

 

 

 

 

 

 

 

logic)

 

COMPULSION

PE:

: A signal to show the status of the drawer switch.(Positive logic)

A signal to show that the paper has run out. Normal at the "LOW" level, but turned to

 

 

the "HIGH" level when the paper has run out.

(3) Power related signal

GND

: Common ground on the circuits

Vcc

: A +5V signal. Connected via a 3.3kΩ resistor.

Page 34
Image 34
Addlogix iDP-3410 user manual Input and Output Signals