11. DRAWER KICK-OUT CONNECTOR AND POWER CONNECTOR
11.1Specifications of Drawer Kick-Out Connector
(1)Drawer
Parallel Interface
Serial Interface
modes.
(2)Electrical characteristics
1)Drive voltage: 24 V DC
2)Drive current: 0.8 A at maximum(Within 510 ms)
3) Switch signal: Signal level | "L" | = 0 | ∼ 0.5 V |
| "H" | = 3 | ∼ 5 V |
11.2 Connector's Pin Configuration
No.
Signal
Function
1 | FG | Frame Ground |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
2 | DRAWER 1 | Drawer 1 drive signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
3 | DRSW | Drawer switch input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
4 | VDR | Drawer drive power |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
5 | DRAWER 2 | Drawer 2 drive signal |
|
|
|
|
|
|
|
|
|
6 | GND | Common ground on the circuit |
|
|
|
|
|
|
|
|
|
Connector used | : | |
Applicable connector | : | |
CAUTION : ∙ | No output is made while printing. | |
∙ | The drawers 1 and 2 cannot be driven simultaneously. |
∙A solenoid used for the drawer should be of 36Ω or more. An output current should be kept below 0.8 A. Use beyond this limit cannot be assured.