iDP-3410  User’s Manual
11. DRAWER KICK-OUT  CONNECTOR AND POWER CONNECTOR
11.1Specifications of Drawer Kick-Out  Connector
(1)Drawer 
Parallel Interface 
Serial Interface 
modes.
(2)Electrical characteristics
1)Drive voltage: 24 V DC
2)Drive current: 0.8 A at maximum(Within 510 ms)
3) Switch signal: Signal level  | "L"  | = 0  | ∼ 0.5 V  | 
  | "H"  | = 3  | ∼ 5 V  | 
11.2 Connector's Pin Configuration
No.
Signal
Function
1  | FG  | Frame Ground  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
2  | DRAWER 1  | Drawer 1 drive signal  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
3  | DRSW  | Drawer switch input  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
4  | VDR  | Drawer drive power  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
5  | DRAWER 2  | Drawer 2 drive signal  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
6  | GND  | Common ground on the circuit  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
Connector used  | :   | |
Applicable connector  | :   | |
CAUTION : ∙  | No output is made while printing.  | |
∙  | The drawers 1 and 2 cannot be driven simultaneously.  | |
∙A solenoid used for the drawer should be of 36Ω or more. An output current should be kept below 0.8 A. Use beyond this limit cannot be assured.
∙This connector cannot be connected to a telephone line. Do not connect other than the solenoid.