iDP-3410 User’s Manual
2.2 Basic Specifications
Model |
|
|
|
| |
|
| ||||
Item |
|
|
|
| |
Printer mechanism |
| ||||
Print method | Serial dot impact method |
| |||
Print width | 64 mm |
| |||
Print head | 9 pins |
| |||
Print speed | Approx. 3 lines/sec. (At | ||||
Print columns | 40 columns or 42 columns (Selectable with the DIP switch) | ||||
Character size | 1.31 mm (W)×3.1 mm (H) |
| |||
Character types | Alphanumeric, International characters, Code page 850, 860, 863, 865, 852, 866, | ||||
| 857; Windows code |
| |||
Line spacing | 4.23 mm(1/6 inch) or 2.82(1/9 inch); |
| |||
| Minimum paper feed pitch 1.41 mm(1/18 inch) |
| |||
Paper | Ordinary paper and | ||||
| |||||
| Copying paper: | ||||
| less |
| |||
Ink ribbon | Special purpose ribbon cartridge, Red/black or single color(black) | ||||
Interface | Serial | ||||
Command system | CBM mode, STAR mode, ESC/POS mode |
| |||
The user can select the mode with the DIP switches and preset jumpers. | |||||
| |||||
Print function | Provided by operating the | ||||
| switches and FEED switch |
| |||
Input buffer | 6 KB or 256 bytes (Selectable with the DIP switch) |
| |||
Buffer backup | Within 24 hours (After 10 minutes or more of printer operation) | ||||
Drawer |
| ||||
Auto loading | Equipped (Automatically feeds the paper by several lines when it is inserted.) | ||||
Paper end detection | Equipped (Stops printing when the paper runs out.) |
| |||
Supply voltage | 120 V AC +/- 10 %, |
| 230 V AC +/- 10 %, | ||
| 50/60 Hz |
| 50/60 Hz | ||
AC adapter |
| ||||
| Output: 26 V DC, 1.15 A |
| |||
Power consumption | Not printing: Approx. 8 W Printing: Approx. 30 W |
| |||
Weight | Main body: 1.25 kg AC adapter: 0.95 kg |
| |||
Outer dimensions | 144 (W) × 233 (D) × 121 (H) mm |
| |||
Operating temperature and | 0∼40 °C, 35∼85 % RH (No dew condensation) |
| |||
humidity |
|
|
|
| |
Storage temperature and |
| ||||
humidity |
|
|
|
| |
Reliability | Print head: 80,000,000 characters |
| |||
| Mechanism: MCBF 2,500,000 lines |
| |||
EMI standard | FCCA |
|
| EN55022 | |
|
| CE Marking | |||
|
|
|
| ||
Safety Standard *1 |
|
|
| TUV GS | |
*1.The AC adapter alone has acquired the Electric Appliances Control Act, UL Standard, | |||||
Standard, and TUV | GS Standard. |
|