B-6 Drive Configuration 62-0162-01
Figure B-6 TRM PWR/TRM ENB Jumper Position
If . . . And . . . Then You Should . . .
Another device is
providing
terminator power
The 4000/7000DLT
Series is not at the
end of the SCSI bus
chain
Connect jumpers as 1 in Figure B-6.
Another device is
providing
terminator power
The 4000/7000DLT
Series is at the end
of the SCSI bus
chain
Connect jumpers as 2 in Figure B-6.
No other device on
the SCSI bus is
providing
terminator power
The 4000/7000DLT
Series is not at the
end of the SCSI bus
chain
Connect jumpers as 3 in Figure B-6.
No other device on
the SCSI bus is
providing
terminator power
The 4000/7000DLT
Series is at the end
of the SCSI bus
chain
Connect jumpers as 4 in Figure B-6.
1NoTerm Power
Disable Active Termination
2NoTerm Power
Enable Active Termination
3Term Pow er
DisableActiveTermination
4Term Pow er
Enable Active Termination