| Appendix D: |
S74.......DTE STOP | Selects the number of asynchronous stop bits. More | |||
|
| than one option can be set at the same time. | ||
|
| 0 | = | 1 stop bit (default) |
|
| 1 | = | 1.5 stop bits |
|
| 2 | = | 2 stop bits |
S75 | DTE FLOW | Selects asynchronous flow control | ||
|
| 0 | = | None (default) |
|
| 1 | = | Hardware flow. CTS from DCE controls DTE. |
|
| 2 | = | Hardware flow. RTS from DTE controls DCE. |
|
| 3 | = | Hardware flow. RTS and CTS flow control. |
|
| 4 | = Software flow. XON/XOFF from DCE controls | |
|
| DTE. |
| |
|
| 8 | = Software flow. XON/XOFF from DTE controls | |
|
| DCE. |
| |
|
| 12 = Software flow. XON/XOFF controls DTE and | ||
|
| DCE. |
| |
S76 | DTE CLOCK | Selects DTE connector transmit clock timing source. | ||
|
| 0 | = | Internal (ISU 2x64 supplies timing) (default) |
|
| 1 | = External (DTE supplies timing) | |
S135 |
| Value determines whether or not the ISDN switch | ||
|
| should consider a DTE port busy. S23 must be pro- | ||
|
| grammed before this register is used. | ||
|
| 0 | = DTE port is not busy (default) | |
|
| 1 | = DTE port is busy |
The following are the string locations for stored numbers 0 - 9:
SS80 | .....SN0 LOC |
SS81 | .....SN1 LOC |
SS82 | .....SN2 LOC |
SS83 | .....SN3 LOC |
SS84 | .....SN4 LOC |
SS85 | .....SN5 LOC |
SS86 | .....SN6 LOC |
SS87 | .....SN7 LOC |
SS88 | .....SN8 LOC |
SS89 | .....SN9 LOC |
S118 | = 0 |
S118 | =32 |
Stored number 0 string Stored number 1 string Stored number 2 string Stored number 3 string Stored number 4 string Stored number 5 string Stored number 6 string Stored number 7 string Stored number 8 string Stored number 9 string CHAP Authentication (default)