Agilent Technologies 2948, 2712A Function A3 Key Sequence A10 Key Sequence, A3/A10 Connection

Models: 2712A 2948

1 137
Download 137 pages 60.86 Kb
Page 103
Image 103

Model 8904A

Service

5.MiscellaneousControl Checks

a. On the Multifunction Synthesizer, press SHIFT PRESET. After the instrument presets, key in

For A3 Output Assembly For A10 Output Assembly

fl (Channel Config.)

fl (Channel Config.)

NEXT

NEXT NEXT

b. Connect a dc coupled, high-impedance oscilloscope or logic probe to the pin of the IC listed in the table below. For each connection, key in the sequences listed in the table (in the order listed)

and note the logic state.

-

~

Function

A3 Key Sequence

A10 Key Sequence

Filter

SHIFT FILTER 1

 

SHIFT FILTER 2

 

fl fl (Filter

Select)

fl fl ( F i l t e r Select)

24 dB Attenuator

AMPTD 1OV

 

AMPTD 1OV

 

625 rnV

 

625 rnV

12 dB Attenuator

1ov

 

1ov

 

2.5V

 

2.5V

6 dB Attenuator

1ov

 

1ov

 

5v

 

5v

On/Off Switch

SHIFT OUTPUT 1 ON

SHIFT OUTPUT 2 ON

 

SHIFT OUTPUT

1 OFF

SHIFT OUTPUT 2 OFF

48 dB Attenuator

AMPTD 1OV

 

AMPTD 10V

 

39 rnV

 

39 rnV

Float/Ground Switch

SHIFT FLOAT 1 ON

SHIFT FLOAT 2 ON

 

SHIFT FLOAT 1

OFF

SHIFT FLOAT 2 OFF

A3/A10 Connection

TTL

IC Pin Level

-

U8 1 L

H

u10 1 H

L

u10 3 H

L

u10 5 H

L

U8 6 L

H

U8 3 H

L

U8 7 L

-H

Troubleshooting (Digital/Output Interface) 8-35