Appendix A Specifications

Agilent Models N5741A – N5752A and N5761A – N5772A

Model

N5741A

N5742A

N5743A

N5744A

N5745A

N5746A

N5747A

N5748A

N5749A

N5750A

N5751A

N5752A

 

N5761A

N5762A

N5763A

N5764A

N5765A

N5766A

N5767A

N5768A

N5769A

N5770A

N5771A

N5772A

Series and Parallel Capability:

Parallel operation

Up to 4 identical units can be connected in master/slave mode with single–wire current balancing

Series operation

Up to 2 identical units can be connected using external protection diodes

Savable states:

In volatile memory 16 (in memory locations 0-15)

Interface Capabilities:

GPIB

SCPI - 1993, IEEE 488.2 compliant interface

LXI Compliance

Class C (only apples to units with the LXI label on the front panel)

USB 2.0

Requires Agilent IO Library version L.01.01 and up, or 14.0 and up

10/100 LAN

Requires Agilent IO Library version L.01.01 and up, or 14.0 and up

Environmental Conditions:

Environment

Indoor use, installation category II (AC input), pollution degree 2

Operating temp.

0°C to 40°C @ 100% load

Storage temp.

–20°C to 70°C

Operating humidity

30% to 90% relative humidity (no condensation)

Storage humidity

10% to 95% relative humidity (no condensation)

Altitude

Up to 3000 meters.

 

Above 2000m, derate the output current by 2%/100m and derate the maximum ambient temperature by 1°C/100m.

 

(For 1500W models from 60V to 600V, derate either the output current or the ambient temperature, but not both.)

LED statement

Any LEDs used in this product are Class 1 LEDs as per IEC 825-1

Regulatory Compliance:

EMC

Complies with the European EMC directive 89/336/EEC for Class A test and measurement products.

 

Complies with the Australian standard and carries the C-Tick mark.

 

This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.

 

Electrostatic discharges >1kV near the I/O connectors may cause the unit to reset and require operator intervention.

Safety

Complies with the European Low Voltage Directive 73/23/EEC and carries the CE-marking.

 

Complies with the US and Canadian safety standards for test and measurement products.

Acoustic Noise Declaration:

Statements provided to comply with requirements of the German Sound Emission Directive, from 18 January 1991: Sound Pressure Lp <70 dB(A), * At Operator Position, * Normal Operation, * According to EN 27779 (Type Test). Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz, * Normaler Betrieb, * Nach EN 27779 (Typprüfung).

Output Terminal Isolation:

6V to 60V units

No output terminal may be more than +/- 60 VDC from any other terminal or chassis ground

80V to 600V units

No output terminal may be more than +/- 600 VDC from any other terminal or chassis ground

AC Input:

Nominal Input

100 – 240 VAC; 50/60Hz

Input Current 750W

10.5A @ 100 VAC nominal; 5A @ 200 VAC nominal

Input Current 1500W

21A @ 100 VAC nominal; 11A @ 200 VAC nominal

Input Range

85 – 265 VAC; 47 – 63 Hz.

Power Factor

0.99 at nominal input and rated output power

Efficiency

76% – 87% for 750W units; 77% – 88% for 1500W units

Inrush Current

< 25A for 750W units; < 50 A for 1500W units

90

Series N5700 User’s Guide

Page 90
Image 90
Agilent Technologies 5751A Series and Parallel Capability, Savable states, Interface Capabilities, Regulatory Compliance

5751A, 5744A, 5743A, 5750A, 5749A specifications

Agilent Technologies has been a leader in electronic measurement and analysis, with a suite of powerful instruments that cater to various applications in research, development, and manufacturing. Among these, the Agilent 5746A, 5745A, 5741A, 5748A, and 5742A models stand out for their advanced capabilities and features.

The Agilent 5746A is a high-performance signal analyzer that excels in time and frequency domain analysis. This device offers a wide frequency range and exceptional dynamic range, making it suitable for both RF and microwave applications. Its advanced digital signal processing allows for high-resolution spectrum analysis and real-time signal processing, which is essential for engineers and researchers working on complex signals.

The Agilent 5745A is known for its versatility as a multifunctional signal generator. It combines the functionalities of a vector signal generator with the precision of a traditional oscillator. This model provides high-quality waveform generation for a variety of modulation schemes, making it ideal for testing communication systems and conducting research in advanced modulation techniques.

The Agilent 5741A is a precision power meter that offers accurate measurements of RF power in a compact format. It is equipped with state-of-the-art sensing technology that ensures reliable and repeatable measurements. The 5741A is particularly useful for monitoring power levels in transmitters and receivers, and its intuitive interface makes it user-friendly for both novices and experienced professionals.

For those focused on harmonic and intermodulation distortion analysis, the Agilent 5748A provides exceptional performance. This model allows users to analyze distortion products in various devices with precision, helping in the design and testing of amplifiers and other RF components. Its comprehensive sweep functionality enables users to observe the behavior of devices across a wide frequency range.

Finally, the Agilent 5742A complements the range with its dedicated spectrum analyzing capabilities. Offering high sensitivity and ability to capture short-lived events, this model is optimal for monitoring transient signals. The 5742A is frequently used in the telecommunications sector to ensure signal integrity and compliance with regulatory standards.

Together, these Agilent Technologies instruments provide a comprehensive toolkit for professionals in electronics and telecommunications, enabling detailed analysis, accurate measurements, and advanced signal generation. Their integration of modern technologies ensures that users can tackle the complexities of today’s electronic environments with confidence and precision.