Appendix A Specifications
Agilent Models N5741A – N5752A and N5761A – N5772A
Model | N5741A | N5742A | N5743A | N5744A | N5745A | N5746A | N5747A | N5748A | N5749A | N5750A | N5751A | N5752A |
| N5761A | N5762A | N5763A | N5764A | N5765A | N5766A | N5767A | N5768A | N5769A | N5770A | N5771A | N5772A |
Series and Parallel Capability:
Parallel operation | Up to 4 identical units can be connected in master/slave mode with |
Series operation | Up to 2 identical units can be connected using external protection diodes |
Savable states:
In volatile memory 16 (in memory locations
Interface Capabilities:
GPIB | SCPI - 1993, IEEE 488.2 compliant interface |
LXI Compliance | Class C (only apples to units with the LXI label on the front panel) |
USB 2.0 | Requires Agilent IO Library version L.01.01 and up, or 14.0 and up |
10/100 LAN | Requires Agilent IO Library version L.01.01 and up, or 14.0 and up |
Environmental Conditions:
Environment | Indoor use, installation category II (AC input), pollution degree 2 |
Operating temp. | 0°C to 40°C @ 100% load |
Storage temp. | |
Operating humidity | 30% to 90% relative humidity (no condensation) |
Storage humidity | 10% to 95% relative humidity (no condensation) |
Altitude | Up to 3000 meters. |
| Above 2000m, derate the output current by 2%/100m and derate the maximum ambient temperature by 1°C/100m. |
| (For 1500W models from 60V to 600V, derate either the output current or the ambient temperature, but not both.) |
LED statement | Any LEDs used in this product are Class 1 LEDs as per IEC |
Regulatory Compliance:
EMC | Complies with the European EMC directive 89/336/EEC for Class A test and measurement products. |
| Complies with the Australian standard and carries the |
| This ISM device complies with Canadian |
| Electrostatic discharges >1kV near the I/O connectors may cause the unit to reset and require operator intervention. |
Safety | Complies with the European Low Voltage Directive 73/23/EEC and carries the |
| Complies with the US and Canadian safety standards for test and measurement products. |
Acoustic Noise Declaration:
Statements provided to comply with requirements of the German Sound Emission Directive, from 18 January 1991: Sound Pressure Lp <70 dB(A), * At Operator Position, * Normal Operation, * According to EN 27779 (Type Test). Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz, * Normaler Betrieb, * Nach EN 27779 (Typprüfung).
Output Terminal Isolation:
6V to 60V units | No output terminal may be more than +/- 60 VDC from any other terminal or chassis ground |
80V to 600V units | No output terminal may be more than +/- 600 VDC from any other terminal or chassis ground |
AC Input:
Nominal Input | 100 – 240 VAC; 50/60Hz |
Input Current 750W | 10.5A @ 100 VAC nominal; 5A @ 200 VAC nominal |
Input Current 1500W | 21A @ 100 VAC nominal; 11A @ 200 VAC nominal |
Input Range | 85 – 265 VAC; 47 – 63 Hz. |
Power Factor | 0.99 at nominal input and rated output power |
Efficiency | 76% – 87% for 750W units; 77% – 88% for 1500W units |
Inrush Current | < 25A for 750W units; < 50 A for 1500W units |
90 | Series N5700 User’s Guide |