OUTPut1 :OVERload?

When OUTPut1:IMPedance is set to either 50or 75Ω, either no output attenuation or 20 dB may be selected. OUTPut1:ATTenuation must be set to

0dB when OUTPut1:IMPedance is set to 0Ω.

Parameters

Parameter

Parameter

 

Range of

Default

 

 

 

Name

Type

 

Values

Units

 

 

 

 

 

 

 

impedance

numeric

 

05075

Ohms

 

 

 

 

MINimumMAXimum

 

 

 

 

 

 

 

MINimum selects 0Ω output impedance; MAXimum selects 75Ω .

 

 

 

 

Comments Coupling group: Power amplifier

 

 

Related commands: SOURce:VOLTage:LEVel:IMMediate:OFFSet and OUTPut1:ATTenuation

*RST Condition: OUTPut1:IMPedance 50

Example Setting 75output impedance

OUTP1:IMP 75

Set 75 output impedance

:OVERload?

OUTPut1:OVERload? determines if an overload condition exists by reading bit 11 of the amplifier’s status register (Appendix C).

Comments A one (1) returned in response to the query indicates an overload condition exists. A zero (0) indicates there is not an overload condition.

Coupling group: none

*RST Condition: none

Example Determining if an overload condition exists

OUTP1:OVER?

determine if overload condition exists

OUTPut1 Subsystem

E1446/E1405/06 Command Reference 3-13

Page 92
Image 92
Agilent Technologies E1446A OUTPut1 OVERload?, OUTPut1 Subsystem E1446/E1405/06 Command Reference, Numeric 05075

E1446A specifications

Agilent Technologies E1446A is a high-performance modular instrument designed for a wide range of applications in the fields of test and measurement. As part of the Agilent family of products, this device exemplifies advanced engineering and innovative technology, catering to the needs of engineers and researchers in various industries.

One of the main features of the E1446A is its dual-channel capability, allowing users to conduct simultaneous measurements, increasing efficiency and reducing test times. The instrument supports a variety of functions, including waveform generation, signal analysis, and frequency measurements. This multifunctionality makes the E1446A a versatile tool for tasks such as automatic test equipment (ATE), signal integrity analysis, and RF testing.

Equipped with state-of-the-art ADCs (Analog-to-Digital Converters) and DACs (Digital-to-Analog Converters), the E1446A ensures high precision and accuracy in measurements. With a bandwidth of up to 500 MHz, it can handle a wide range of signals, making it suitable for both low-frequency and high-frequency applications. The instrument supports various input signal types, including sine, square, and custom waveforms, expanding its applicability across diverse testing scenarios.

The E1446A also integrates advanced digital signal processing capabilities, allowing for real-time analysis and manipulation of signals. This feature is particularly useful in applications requiring immediate feedback and adjustment, such as radar and communications testing. Furthermore, the modular design facilitates easy upgrades and customization, enabling users to adapt the instrument to their ever-evolving testing requirements.

User-friendliness is another hallmark of the E1446A. It features a straightforward interface, designed for intuitive operation, which reduces the learning curve for new users. Additionally, the instrument is compatible with various programming languages, including SCPI, making it easy to integrate into existing test systems and automate testing processes.

Finally, the E1446A's compact form factor and rugged design allow for deployment in demanding environments, fulfilling the needs of both laboratory and field applications. With its blend of precision, versatility, and ease of use, the Agilent Technologies E1446A remains a vital instrument for engineers and researchers looking for dependable test and measurement solutions. Its capabilities continue to support innovation across a spectrum of technological advancements.