Printing History

The Printing History shown below lists all Editions and Updates of this manual and the printing date(s). The first printing of the manual is Edition 1. The Edition number increments by 1 whenever the manual is revised. Updates, which are issued between Editions, contain replacement pages to correct the current Edition of the manual. Updates are numbered sequentially starting with Update 1. When a new Edition is created, it contains all the Update information for the previous Edition. Each new Edition or Update also includes a revised copy of this printing history page. Many product updates or revisions do not require manual changes and, conversely, manual corrections may be done without accompanying product changes. Therefore, do not expect a one-to-one correspondence between product updates and manual updates.

Edition 1 (Part Number E1446-90001). . . . . . . . . . . . . . . . . . . . . . . . . May 1992

Edition 1 Rev 2 (Part Number E1446-90001) . . . . . . . . . . . . . . . . . . . May 2006

Safety Symbols

Instruction manual symbol affixed to product. Indicates that the user must refer to the man- ual for specific WARNING or CAUTION information to avoid personal injury or dam- age to the product.

 

Indicates the field wiring terminal that must

 

 

be connected to earth ground before operating

 

 

the equipment—protects against electrical

WARNING

 

shock in case of fault.

or

Frame or chassis ground terminal—typically

CAUTION

 

connects to the equipment’s metal frame.

 

Alternating current (AC).

Direct current (DC).

Indicates hazardous voltages.

Calls attention to a procedure, practice, or con- dition that could cause bodily injury or death.

Calls attention to a procedure, practice, or con- dition that could possibly cause damage to equipment or permanent loss of data.

WARNINGS

The following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. Agilent Technologies assumes no liability for the customer’s failure to comply with these requirements.

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal), an uninterruptible safety earth ground must be provided from the mains power source to the product input wiring terminals or supplied power cable.

DO NOT operate the product in an explosive atmosphere or in the presence of flammable gases or fumes.

For continued protection against fire, replace the line fuse(s) only with fuse(s) of the same voltage and current rating and type. DO NOT use repaired fuses or short-circuited fuse holders.

Keep away from live circuits: Operating personnel must not remove equipment covers or shields. Procedures involving the removal of covers or shields are for use by service-trained personnel only. Under certain conditions, dangerous voltages may exist even with the equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless you are qualified to do so.

DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built into this product have been impaired, either through physical damage, excessive moisture, or any other reason, REMOVE POWER and do not use the product until safe operation can be verified by service-trained personnel. If necessary, return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained.

DO NOT service or adjust alone: Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.

DO NOT substitute parts or modify equipment: Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to an Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained.

6 Agilent E1446A Summing Amplifier/DAC User’s Manual

Page 7
Image 7
Agilent Technologies E1446A user manual Printing History

E1446A specifications

Agilent Technologies E1446A is a high-performance modular instrument designed for a wide range of applications in the fields of test and measurement. As part of the Agilent family of products, this device exemplifies advanced engineering and innovative technology, catering to the needs of engineers and researchers in various industries.

One of the main features of the E1446A is its dual-channel capability, allowing users to conduct simultaneous measurements, increasing efficiency and reducing test times. The instrument supports a variety of functions, including waveform generation, signal analysis, and frequency measurements. This multifunctionality makes the E1446A a versatile tool for tasks such as automatic test equipment (ATE), signal integrity analysis, and RF testing.

Equipped with state-of-the-art ADCs (Analog-to-Digital Converters) and DACs (Digital-to-Analog Converters), the E1446A ensures high precision and accuracy in measurements. With a bandwidth of up to 500 MHz, it can handle a wide range of signals, making it suitable for both low-frequency and high-frequency applications. The instrument supports various input signal types, including sine, square, and custom waveforms, expanding its applicability across diverse testing scenarios.

The E1446A also integrates advanced digital signal processing capabilities, allowing for real-time analysis and manipulation of signals. This feature is particularly useful in applications requiring immediate feedback and adjustment, such as radar and communications testing. Furthermore, the modular design facilitates easy upgrades and customization, enabling users to adapt the instrument to their ever-evolving testing requirements.

User-friendliness is another hallmark of the E1446A. It features a straightforward interface, designed for intuitive operation, which reduces the learning curve for new users. Additionally, the instrument is compatible with various programming languages, including SCPI, making it easy to integrate into existing test systems and automate testing processes.

Finally, the E1446A's compact form factor and rugged design allow for deployment in demanding environments, fulfilling the needs of both laboratory and field applications. With its blend of precision, versatility, and ease of use, the Agilent Technologies E1446A remains a vital instrument for engineers and researchers looking for dependable test and measurement solutions. Its capabilities continue to support innovation across a spectrum of technological advancements.