Agilent Technologies FS2331 Software Requirements System Software, Setting up the 167xx Analyzer

Models: FS2331

1 55
Download 55 pages 28.73 Kb
Page 16
Image 16

Software Requirements

System Software

The FS2331 Probe requires version A.02.70.00 (or later) of the 16700 System Operating Software. You can check to see if you already have the correct version by opening the “System Administration” dialog and selecting the “Show Version” button. If you do not have the correct version then you must update your system software. Please consult 16700 system documentation for the SW update procedure.

Setting up the 167xx Analyzer

The floppy disk(s) supplied with the FS2331 DDR Probe contains the software required to operate the FS2331. Install the Inverse Assembler and Configuration files from the floppy using the 16700 software installation procedure. This will install an inverse assembler called “IFS2331E” in the standard location for inverse assemblers, and will install several configuration files in the /logic/configs/FuturePlus/FS2331 directory that allow you to easily configure the analyzer for timing or state operation with the FS2331. See the sections below for information on which configuration file to use for your application.

Setting up the 169xx Analyzer

A CD containing the 16900 software is included in the FS2331 package. The CD contains a setup file that will automatically install the configuration files and protocol decoder onto a PC containing the 16900 operating system or onto a 16900 analyzer itself.

To install the software simply double click the .exe file on the CD containing the 16900 software. After accepting the license agreement the software should install within a couple of minutes.

169xx Licensing

Once the software has been successfully installed you must license the software. Please refer to the entitlement certificate for instructions on licensing the software. The software can only be installed on one machine. If you need to install the software on more than one machine you must contact the FuturePlus sales department to purchase additional licenses.

Loading 169xx configuration files and define probes feature

When the software has been licensed you should be ready to load a configuration file. You can access the configuration files by clicking on the folder that was placed on the desktop. When you click on the folder it should open up to display all the configuration files to choose from. If you put your mouse cursor on the name of the file a description will appear telling you what the setup consists of, once you choose the configuration file that is appropriate for your configuration the 169xx operating system should execute.

The protocol decoder automatically loads when the configuration file is loaded. If the decoder does not load, you may load it by selecting tools from the menu bar at the top of the screen and select the decoder from the list.

After loading the configuration file of choice, go into the format specification of the configuration by choosing Setup from the menu bar and then selecting Bus/Signal in the drop down menu. When the format specification appears press Define Probes at the bottom of the screen. The Define Probes feature will describe how to hook the analyzer cards to the connections on the target. The following figure shows what the Define Probes screen looks like. The figure below may differ from your display; this is an example of how the display looks in general.

16

Page 16
Image 16
Agilent Technologies FS2331 Software Requirements System Software, Setting up the 167xx Analyzer, 169xx Licensing