Basic Commands

These commands are common to most communication devices using AT Com- mands.

TABLE 3. Basic Commands (common AT commands)

Command

Parameters

Details

 

 

 

+++

none

AT Escape sequence.

The "+" is ASCII 0x2B.

 

Not proceeded by AT.

 

 

If the Raven is in a data mode (any mode other than

 

 

PassThru), this command causes the modem to re-enter

 

 

AT command mode.

 

 

There must be an idle time (set by S50) on the serial port

 

 

before and after this command.

 

 

The detection of +++ is disabled if DAE=1.

 

 

 

A/

none

Re-execute last command.

 

 

Not proceeded by AT.

 

 

 

A

none

Answer - manual

 

 

 

DAE=n

n=0 or 1

Disable AT Escape Sequence detection.

 

 

0 : Enable +++ AT escape sequence detection.

 

 

1 : Disable +++ AT escape sequence detection.

 

 

 

En

n=0 or 1

Toggle AT command echo mode.

 

 

0 : Echo Off

 

 

1 : Echo On

 

 

 

Hn

n=1

Hang-Up Command.

 

 

1: Hang-up

 

 

Note: With an AT telnet connection, this command will

 

 

terminate the host data mode and return the Raven to an

 

 

AT mode.

 

 

 

O

none

Online (Remote): Causes the Raven to go from Com-

 

 

mand State to data state.

 

 

 

Raven CDMA User Guide for Verizon, version 2.23