TABLE 16. Modbus Settings

Command

Parameters

Details

 

 

 

MVMSK=hh

hh=hex value

Modbus Variant ID Mask.

 

00 - no mask, all

Byte hex mask to use when extracting the ID. Specify

 

8 bits (default)

which bits in the ID field to use. This parameter is used

 

0F - only the

when the when the Mode Default (MD) is set to hex 63.

 

Cannot be configured in Wireless ACE.

 

low order 4 bits

 

 

 

MVOFF=n

n = 0 - 255

Modbus (variable mode) Offset.

 

 

Indicates the offset in the data of where the Modbus ID

 

 

starts.

 

 

Cannot be configured in Wireless ACE.

 

 

 

MVOPT=n

n= 0 or

Modbus Variant Option.

 

 

Sets various behavioral options when dealing with a

 

 

Modbus-variant protocol. This parameter is used when

 

 

the when MD is set to hex 63.

 

 

0 : No special action (Default).

 

 

1 : Skip leading zeroes in Modbus packets.

 

 

Cannot be configured in Wireless ACE.

 

 

 

MVTYP=n

n=0 1 2

Modbus Variant Type.

 

 

The data-type of the RTU ID in a modbus-variant proto-

 

 

col. This parameter is used to define the data-type of the

 

 

RTU ID in Modbus-like protocol data packets. This

 

 

parameter is used when MD is set to 63.

 

 

0 : Binary (Default)

 

 

1 : ASCII Hex

 

 

2 : ASCII Decimal

 

 

Cannot be configured in Wireless ACE.

 

 

 

84

Raven CDMA User Guide for Verizon, version 2.23

Page 90
Image 90
Airlink CDMA/1x manual Low order 4 bits