TABLE 13. Keepalive

Command

Parameters

Details

 

 

 

*MINXMIT=n

n=seconds

Minimum transmit period enforcement. When set to n

 

 

seconds, will not let the *IPPING, *PPMINTIME, and

 

 

the *MSCIUPDPERIOD timers to be set less than n sec-

 

 

onds.

 

 

Note that the *PPTIME can still be set to less than

 

 

*MINXMIT, but the packets will still be transmitted no

 

 

more often than the *PPMINTIME.

 

 

Warning: The *MINXMIT value is can only be set one

 

 

time and AirLink must be contacted to reset it.

 

 

 

IP Manager

IP Manager (page 15) is a service from AirLink which allows a Raven with a dynamic IP to be contacted as if it had a static IP by using a Fully Qualified Domain Name.

TABLE 14. IP Manager

Command

Parameters

Details

 

 

 

*DOMAIN=[name]

name = domain

Domain (or domain zone) of which the Raven is a part.

 

name (i.e. eair-

This value is used during name resolutions if a fully

 

link.com)

qualified name is not provided and also for DNS

 

 

updates. This value can be up to 20 characters long.

 

 

If *DOMAIN=eairlink.com, then when

 

 

ATDT@remote1 is entered, the fully qualified name

 

 

remote1.eairlink.com will be used to perform a DNS

 

 

query to resolve the name to an IP address.

 

 

Note: Only letters, numbers, hyphens, and periods can

 

 

be used.

 

 

 

*IPMANAGERn=[name]

n= 1 or 2

Sets a domain name or IP address to send IP change noti-

 

name = domain

fications to. Up to two independent IP Manager servers

 

can be set, using either AT*IPMANAGER1 or

 

name

 

AT*IPMANAGER2. Updates to a server can be disabled

 

 

 

 

by setting that entry to nothing (i.e.

 

 

"AT*IPMANAGER1=").

 

 

 

Raven CDMA User Guide for Verizon, version 2.23

79

Page 85
Image 85
Airlink CDMA/1x manual IP Manager, If *DOMAIN=eairlink.com, then when