Specifications and Dimensions
Specifications |
| 25 Pound |
| 30 Pound | T30 | 35 Pound | |
|
|
|
|
|
| ||
Noise level measured during operation at |
|
|
|
|
| ||
operator position of 3.3 feet (1 meter) in | 60 dBA |
| 61 dBA | 63 dBA | 66 dBA | ||
front of machine and 5.2 feet (1.6 meters) |
| ||||||
|
|
|
|
| |||
from floor |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Net Weight (approximate): |
| 300 |
| 330 | 550 | 360 | |
Pounds (kg) |
| (137) |
| (150) | (250) | (163) | |
|
|
|
|
|
|
| |
Cylinder Size: |
| 26.5 x 24 |
| 26.5 x 30 | 30 x 26 | 30 x 30 | |
Inches (mm) |
| (673 x 610) |
| (673 x 762) | (762 x 660) | (762 x 762) | |
|
|
|
|
|
|
| |
Cylinder Capacity (dry weight): |
| 25 |
| 30 | 2 x 30 | 35 | |
Pounds (kg) |
| (11.3) |
| (13.6) | (2 x 13.6) | (15.9) | |
|
|
|
|
|
|
| |
Drive Motor Horsepower |
| 1/4 |
| 1/4 | 1/4** | 1/4 | |
|
|
|
|
|
|
| |
Fan Motor Horsepower |
| 1/4 |
| 1/4 | 1/4** | 1/4 | |
|
|
|
|
|
|
|
|
|
| 50 Hertz | 410 |
| 410 | 320** | 470 |
Maximum Airflow per |
|
| (194) |
| (194) | (151) | (222) |
|
|
|
|
|
|
| |
Pocket: C.F.M. (l/sec) |
| 60 Hertz | 450 |
| 450 | 350** | 520 |
|
|
| (212) |
| (212) | (165) | (245) |
|
|
|
|
|
|
|
|
Maximum Static Back |
| 50 Hertz | 0.6 |
| 0.6 | 0.8* | 0.5 |
|
| (1.5) |
| (1.5) | (2.0) | (1.3) | |
Pressure: Inches W.C. |
|
|
|
|
|
|
|
| 60 Hertz | 0.8 |
| 0.8 | 0.9* | 0.6 | |
(mbar) |
|
| |||||
|
|
| (2.0) |
| (2.0) | (2.3) | (1.5) |
|
|
|
|
|
|
|
|
|
|
| Gas Models |
|
|
| |
|
|
|
|
|
|
| |
Gas Connection |
| 1/2 in. NPT |
| 1/2 in. NPT | 1/2 in. NPT | 1/2 in. NPT | |
|
|
|
|
|
|
| |
Gas Consumption: |
| 64,000 |
| 73,000 | 73,000** | 90,000 | |
Btu/hr (kW, Mj/hr) |
| (18.7, 67.5) |
| (21.4, 77) | (21.4, 77) | (26.4, 95) | |
|
|
|
|
|
|
|
|
|
|
| Electric Models |
|
|
| |
|
|
|
|
|
|
|
|
Heating Element |
| 400/50/3 | 10 kW |
| 21 kW | 21 kW** | 24 kW |
|
|
|
| ||||
| Standard | 12 kW |
| ||||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| Steam Models |
|
|
| |
|
|
|
|
|
|
| |
Steam Connection |
| 3/4 in. NPT |
| 3/4 in. NPT | 3/4 in. NPT | 3/4 in. NPT | |
|
|
|
|
|
| ||
Steam Consumption at 100 psig (6.9 bar): | 3.5 |
| 3.5 | 2.8** | 4.0 | ||
Boiler Horsepower (Btu/hr) |
| (121,000) |
| (121,000) | (97,000) | (137,000) | |
|
|
|
|
|
| ||
Steam Consumption at 15 psig (1.0 bar): | 2.4 |
| 2.4 | 2.0** | 2.8 | ||
Boiler Horsepower (Btu/hr) |
| (81,000) |
| (81,000) | (68,000) | (95,000) | |
|
|
|
|
|
|
|
|
*with both pockets running **for each pocket
70269701 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 13 |