Steam Requirements
SUPPLY
2
1
4
9 | 3 |
|
10
5
|
|
|
|
| 6 |
|
|
| 8 |
|
| 4 |
|
|
|
|
|
|
| |
|
|
|
|
|
| RETURN |
|
| 7 |
|
|
|
|
|
| 6 | 5 |
|
| T473I |
|
|
| 10 |
|
| |
|
|
|
|
|
| |
Note: Refer to Table 15 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number | ||||||
of elbows. |
|
|
|
|
| |
1 | Steam Coil |
|
| 6 | Trap with | |
2 | 12 in. (305 mm) Riser |
| 7 | Vacuum Breaker (Optional) | ||
3 | Condensate Return Line from Supply Line | 8 | 18 in. (457 mm) Drop | |||
4 |
|
| 9 | Solenoid Valve (Supplied with machine) | ||
5 | Check Valve |
|
| 10 | Union |
|
|
|
|
| Figure 15 |
|
|
| Model | Steam Pressure | Minimum Pipe Diameter | Steam Trap Size * | ||
| PSI (bar) |
| (Pounds Condensate/Hour) | |||
|
|
|
|
| ||
25/30 Pound | 3/4 in. NPT | 134 | ||||
| T30 | 3/4 in. NPT | 110 | |||
| 35 Pound | 3/4 in. NPT | 166 | |||
* Based on 100 PSI. |
|
| Table 15 |
|
| |
|
|
|
|
|
|
70269701 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 59 |