Steam Requirements

SUPPLY

2

1

4

9

3

 

10

5

 

 

 

 

 

6

 

 

 

8

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN

 

 

7

 

 

 

 

 

 

6

5

 

 

T473I

 

 

 

10

 

 

 

 

 

 

 

 

Note: Refer to Table 15 for sizing of steam lines. Piping must also be sized accordingly for length of runs, and number

of elbows.

 

 

 

 

 

1

Steam Coil

 

 

6

Trap with Built-In Strainer

2

12 in. (305 mm) Riser

 

7

Vacuum Breaker (Optional)

3

Condensate Return Line from Supply Line

8

18 in. (457 mm) Drop

4

Shut-Off Valve

 

 

9

Solenoid Valve (Supplied with machine)

5

Check Valve

 

 

10

Union

 

 

 

 

 

Figure 15

 

 

 

Model

Steam Pressure

Minimum Pipe Diameter

Steam Trap Size *

 

PSI (bar)

 

(Pounds Condensate/Hour)

 

 

 

 

 

25/30 Pound

15-100 (1-6.9)

3/4 in. NPT

134

 

T30

15-100 (1-6.9)

3/4 in. NPT

110

 

35 Pound

15-100 (1-6.9)

3/4 in. NPT

166

* Based on 100 PSI.

 

 

Table 15

 

 

 

 

 

 

 

 