Electrical Requirements

For T30 Gas and Steam Models(For Total Machine):

 

Terminal Block

 

Recommended

 

Recommended

Serial Plate

Current

Fuse or

Breaker

Minimum

Connections

Voltage

(Amps)

Breaker Rating

Poles

Conductor Size

Required

 

 

(Amps)

 

[AWG (mm2)]

120V/60 Hz/1ph

L1, Neutral,

16.0

20

1

12 (3.31)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-240V/60Hz/

L1, L2, Neutral,

8.0

10

2

14 (2.08)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

100V/60Hz/1ph

L1, Neutral,

22.0

30

1

10 (5.26)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200-220V/60Hz/

L1, Neutral,

11.6

15

1

14 (2.08)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

100V/50Hz/1ph

L1, Neutral,

24.2

35

1

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/1ph

L1, Neutral,

15.0

20

1

12 (3.31)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/

L1, Neutral,

15.0

20

1

12 (3.31)

1ph

and ground

 

 

 

 

 

 

 

 

 

 

200-208V/60Hz/

L1, L2, L3,

6.4

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3,

6.4

10*

3

14 (2.08)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V/50Hz/3ph

L1, L2, L3,

5.8

10*

3

14 (2.08)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/

L1, L2, L3,

7.0

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

380V/50Hz/3ph

L1, L2, L3,

3.0

10*

3

14 (2.08)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400-415V/50Hz/

L1, L2, L3,

3.2

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

460-480V/60Hz/

L1, L2, L3,

3.3

10*

3

14 (2.08)

3ph

and ground

 

 

 

 

 

 

 

 

 

 

*3 Phase machines should not have fuses, breakers only.

Table 10

70269701

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

53